Objectives: The effect of preanalytical and analytical factors on the α-synuclein (α-syn) seed amplification assay's (SAA) performance has not been fully explored. Similarly, there is limited knowledge about the most suitable assay protocol and kinetic parameters for misfolded α-syn seed quantification. Methods: We studied the effect of centrifugation, repeated freeze-thaw cycles (up to seven), delayed freezing, detergent addition, and blood contamination on the performance of the cerebrospinal fluid (CSF) α-syn SAA real-time quaking-induced conversion (RT-QuIC). Moreover, we analysed the inter- and intra-plate variability, the recombinant protein batch effect, and the RT-QuIC parameters' variability when multiple samples were run in controlled conditions. Finally, we evaluated the assay potential of quantifying α-syn seed by assessing kinetic curves in serial CSF dilutions. Results: Among tested preanalytical variables, a ≥0.01 % blood contamination and adding detergents significantly affected the RT-QuIC kinetic parameters and the number of positive replicates. Increasing the number of replicates improved result reproducibility. The number of positive replicates in serially diluted CSF samples improved discrimination between samples with high and low seeding activity, and the time to threshold (LAG) was the most reliable kinetic parameter in multiple experiment settings. Conclusions: Preanalytical variables affecting α-syn RT-QuIC performance are limited to blood contamination and detergent addition. The number of positive replicates and the LAG are the most reliable variables for quantifying α-syn seeding activity. Their consistent measurement in serial dilution experiments, especially when associated with an increased number of sample replicates, will help to develop the α-syn RT-QuIC assay further into a quantitative test.

Improving protocols for α-synuclein seed amplification assays: Analysis of preanalytical and analytical variables and identification of candidate parameters for seed quantification / Mammana, A., Baiardi, S., Rossi, M., Quadalti, C., Ticca, A., Magliocchetti, F., Bernhardt, A., Capellari, S., Parchi, P.. - In: CLINICAL CHEMISTRY AND LABORATORY MEDICINE. - ISSN 1434-6621. - 62:10(2024), pp. 2001-2010. [10.1515/cclm-2023-1472]

Improving protocols for α-synuclein seed amplification assays: Analysis of preanalytical and analytical variables and identification of candidate parameters for seed quantification

Rossi M.;
2024

Abstract

Objectives: The effect of preanalytical and analytical factors on the α-synuclein (α-syn) seed amplification assay's (SAA) performance has not been fully explored. Similarly, there is limited knowledge about the most suitable assay protocol and kinetic parameters for misfolded α-syn seed quantification. Methods: We studied the effect of centrifugation, repeated freeze-thaw cycles (up to seven), delayed freezing, detergent addition, and blood contamination on the performance of the cerebrospinal fluid (CSF) α-syn SAA real-time quaking-induced conversion (RT-QuIC). Moreover, we analysed the inter- and intra-plate variability, the recombinant protein batch effect, and the RT-QuIC parameters' variability when multiple samples were run in controlled conditions. Finally, we evaluated the assay potential of quantifying α-syn seed by assessing kinetic curves in serial CSF dilutions. Results: Among tested preanalytical variables, a ≥0.01 % blood contamination and adding detergents significantly affected the RT-QuIC kinetic parameters and the number of positive replicates. Increasing the number of replicates improved result reproducibility. The number of positive replicates in serially diluted CSF samples improved discrimination between samples with high and low seeding activity, and the time to threshold (LAG) was the most reliable kinetic parameter in multiple experiment settings. Conclusions: Preanalytical variables affecting α-syn RT-QuIC performance are limited to blood contamination and detergent addition. The number of positive replicates and the LAG are the most reliable variables for quantifying α-syn seeding activity. Their consistent measurement in serial dilution experiments, especially when associated with an increased number of sample replicates, will help to develop the α-syn RT-QuIC assay further into a quantitative test.
2024
62
10
2001
2010
Improving protocols for α-synuclein seed amplification assays: Analysis of preanalytical and analytical variables and identification of candidate parameters for seed quantification / Mammana, A., Baiardi, S., Rossi, M., Quadalti, C., Ticca, A., Magliocchetti, F., Bernhardt, A., Capellari, S., Parchi, P.. - In: CLINICAL CHEMISTRY AND LABORATORY MEDICINE. - ISSN 1434-6621. - 62:10(2024), pp. 2001-2010. [10.1515/cclm-2023-1472]
Mammana, A.; Baiardi, S.; Rossi, M.; Quadalti, C.; Ticca, A.; Magliocchetti, F.; Bernhardt, A.; Capellari, S.; Parchi, P.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1415510
Citazioni
  • ???jsp.display-item.citation.pmc??? 25
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 36
  • OpenAlex 36
social impact