To investigate the macular quantitative parameters interchangeability of three different optical coherence tomography angiography (OCT-A) angiocubes (i.e., 3 Ã 3, 6 Ã 6, and 12 Ã 12 mm) on healthy subjects and patients affected by diabetic retinopathy (DR) and to assess the interrater reliability of such indices across the different scan protocols. METHODS. Retrospective study involving 20 eyes of healthy subjects and 20 eyes with DR. All eyes underwent swept-source OCT-A with 3 Ã 3-, 6 Ã 6-, and 12 Ã 12-mm angiocubes centered on the fovea. Foveal avascular zone (FAZ) area and vessel density on 3 Ã 3-, 6 Ã 6-, and 12 Ã 12-mm macular scans were calculated by three independent operators at all retina, superficial, deep, and choriocapillary vascular layers. Interchangeability and interrater reliabilities were estimated using intraclass correlation coefficient (ICC). RESULTS. Interscan reproducibility of FAZ area was very strong (ICC > 0.85) at every plexus. On the contrary, vessel density values significantly varied across different scan sizes (ICC < 0.51). Intrascan interrater reliability was high for all retina and superficial FAZ areas, while it was satisfactory at deep capillary plexus only for 3 Ã 3-mm scan. CONCLUSIONS. FAZ area at all plexuses is a robust parameter even if calculated on angiocubes with different size. However, interrater reliability is higher when measured in smaller scans. Conversely, vessel density results depend on the size of angiocube, although their interrater reliability is extremely high. Studies involving OCT-A should take into consideration that scan size may influence macular perfusion parameters and interrater reliability.

Macular perfusion parameters in different angiocube sizes: Does the size matter in quantitative optical coherence tomography angiography? / Rabiolo, A., Gelormini, F., Marchese, A., Cicinelli, M.V., Triolo, G., Sacconi, R., Querques, L., Bandello, F., Querques, G.. - In: INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE. - ISSN 0146-0404. - 59:1(2018), pp. 231-237. [10.1167/iovs.17-22359]

Macular perfusion parameters in different angiocube sizes: Does the size matter in quantitative optical coherence tomography angiography?

Querques, Giuseppe
2018

Abstract

To investigate the macular quantitative parameters interchangeability of three different optical coherence tomography angiography (OCT-A) angiocubes (i.e., 3 Ã 3, 6 Ã 6, and 12 Ã 12 mm) on healthy subjects and patients affected by diabetic retinopathy (DR) and to assess the interrater reliability of such indices across the different scan protocols. METHODS. Retrospective study involving 20 eyes of healthy subjects and 20 eyes with DR. All eyes underwent swept-source OCT-A with 3 Ã 3-, 6 Ã 6-, and 12 Ã 12-mm angiocubes centered on the fovea. Foveal avascular zone (FAZ) area and vessel density on 3 Ã 3-, 6 Ã 6-, and 12 Ã 12-mm macular scans were calculated by three independent operators at all retina, superficial, deep, and choriocapillary vascular layers. Interchangeability and interrater reliabilities were estimated using intraclass correlation coefficient (ICC). RESULTS. Interscan reproducibility of FAZ area was very strong (ICC > 0.85) at every plexus. On the contrary, vessel density values significantly varied across different scan sizes (ICC < 0.51). Intrascan interrater reliability was high for all retina and superficial FAZ areas, while it was satisfactory at deep capillary plexus only for 3 Ã 3-mm scan. CONCLUSIONS. FAZ area at all plexuses is a robust parameter even if calculated on angiocubes with different size. However, interrater reliability is higher when measured in smaller scans. Conversely, vessel density results depend on the size of angiocube, although their interrater reliability is extremely high. Studies involving OCT-A should take into consideration that scan size may influence macular perfusion parameters and interrater reliability.
2018
59
1
231
237
Macular perfusion parameters in different angiocube sizes: Does the size matter in quantitative optical coherence tomography angiography? / Rabiolo, A., Gelormini, F., Marchese, A., Cicinelli, M.V., Triolo, G., Sacconi, R., Querques, L., Bandello, F., Querques, G.. - In: INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE. - ISSN 0146-0404. - 59:1(2018), pp. 231-237. [10.1167/iovs.17-22359]
Rabiolo, Alessandro; Gelormini, Francesco; Marchese, Alessandro; Cicinelli, Maria Vittoria; Triolo, Giacinto; Sacconi, Riccardo; Querques, Lea; Bandel...espandi
File in questo prodotto:
File Dimensione Formato  
i1552-5783-59-1-231.pdf

Open access

Tipologia: VOR - Versione pubblicata dall'editore
Licenza: [IR] creative-commons
Dimensione 988.18 kB
Formato Adobe PDF
988.18 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1404581
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 59
  • ???jsp.display-item.citation.isi??? 56
social impact