Introduction: In current clinical practice, several optical coherence tomography (OCT) biomarkers have been proposed for the assessment of severity and prognosis of different retinal diseases. Subretinal pseudocysts are subretinal cystoid spaces with hyperreflective borders and only a few single cases have been reported thus far. The aim of the study was to characterize and investigate this novel OCT finding, exploring its clinical outcome.Methods: Patients were evaluated retrospectively across different centers. The inclusion criterion was the presence of subretinal cystoid space on OCT scans, regardless of concurrent retinal diseases. Baseline examination was set as the first time the subretinal pseudocyst was identified by OCT. Medical and ophthalmological histories were collected at baseline. OCT and OCT-angiography were performed at baseline and at each follow-up examination.Results: Twenty-eight eyes were included in the study and 31 subretinal pseudocysts were characterized. Out of 28 eyes, 16 were diagnosed with neovascular age-related macular degeneration (AMD), 7 with central serous chorioretinopathy, 4 with diabetic retinopathy, and 1 with angioid streaks. Subretinal and intraretinal fluid were present in 25 and 13 eyes, respectively. Mean distance of the subretinal pseudocyst from the fovea was 686 mu m. The diameter of the pseudocyst was positively associated with the height of the subretinal fluid (r = 0.46; p = 0.018) and central macular thickness (r = 0.612; p = 0.001). At follow-up, subretinal pseudocysts disappeared in most of the reimaged eyes (16 out of 17). Of these, two patients presented retinal atrophy at baseline examination and eight patients (47%) developed retinal atrophy at follow-up. Conversely, seven eyes (41%) did not develop retinal atrophy.Conclusion: Subretinal pseudocysts are precarious OCT findings, usually disclosed in a context of subretinal fluid, and are probably transient alterations within the photoreceptor outer segments and retinal pigment epithelium (RPE) layer. Despite their nature, subretinal pseudocysts have been associated with photoreceptor loss and incomplete RPE definition.

Subretinal Pseudocysts: A Comprehensive Analysis of this Novel OCT Finding / Menean, M., Sacconi, R., Vujosevic, S., Kesim, C., Quarta, A., Ribarich, N., Bottazzi, L., Hilely, A., Capuano, V., Souied, E.H., Sarraf, D., Bandello, F., Querques, G.. - In: OPHTHALMOLOGY AND THERAPY. - ISSN 2193-8245. - 12:4(2023), pp. 2035-2048. [10.1007/s40123-023-00727-8]

Subretinal Pseudocysts: A Comprehensive Analysis of this Novel OCT Finding

Querques, Giuseppe
2023

Abstract

Introduction: In current clinical practice, several optical coherence tomography (OCT) biomarkers have been proposed for the assessment of severity and prognosis of different retinal diseases. Subretinal pseudocysts are subretinal cystoid spaces with hyperreflective borders and only a few single cases have been reported thus far. The aim of the study was to characterize and investigate this novel OCT finding, exploring its clinical outcome.Methods: Patients were evaluated retrospectively across different centers. The inclusion criterion was the presence of subretinal cystoid space on OCT scans, regardless of concurrent retinal diseases. Baseline examination was set as the first time the subretinal pseudocyst was identified by OCT. Medical and ophthalmological histories were collected at baseline. OCT and OCT-angiography were performed at baseline and at each follow-up examination.Results: Twenty-eight eyes were included in the study and 31 subretinal pseudocysts were characterized. Out of 28 eyes, 16 were diagnosed with neovascular age-related macular degeneration (AMD), 7 with central serous chorioretinopathy, 4 with diabetic retinopathy, and 1 with angioid streaks. Subretinal and intraretinal fluid were present in 25 and 13 eyes, respectively. Mean distance of the subretinal pseudocyst from the fovea was 686 mu m. The diameter of the pseudocyst was positively associated with the height of the subretinal fluid (r = 0.46; p = 0.018) and central macular thickness (r = 0.612; p = 0.001). At follow-up, subretinal pseudocysts disappeared in most of the reimaged eyes (16 out of 17). Of these, two patients presented retinal atrophy at baseline examination and eight patients (47%) developed retinal atrophy at follow-up. Conversely, seven eyes (41%) did not develop retinal atrophy.Conclusion: Subretinal pseudocysts are precarious OCT findings, usually disclosed in a context of subretinal fluid, and are probably transient alterations within the photoreceptor outer segments and retinal pigment epithelium (RPE) layer. Despite their nature, subretinal pseudocysts have been associated with photoreceptor loss and incomplete RPE definition.
2023
12
4
2035
2048
Subretinal Pseudocysts: A Comprehensive Analysis of this Novel OCT Finding / Menean, M., Sacconi, R., Vujosevic, S., Kesim, C., Quarta, A., Ribarich, N., Bottazzi, L., Hilely, A., Capuano, V., Souied, E.H., Sarraf, D., Bandello, F., Querques, G.. - In: OPHTHALMOLOGY AND THERAPY. - ISSN 2193-8245. - 12:4(2023), pp. 2035-2048. [10.1007/s40123-023-00727-8]
Menean, Matteo; Sacconi, Riccardo; Vujosevic, Stela; Kesim, Cem; Quarta, Alberto; Ribarich, Nicolò; Bottazzi, Leonardo; Hilely, Assaf; Capuano, Vittor...espandi
File in questo prodotto:
File Dimensione Formato  
s40123-023-00727-8.pdf

Open access

Tipologia: VOR - Versione pubblicata dall'editore
Licenza: [IR] creative-commons
Dimensione 1.35 MB
Formato Adobe PDF
1.35 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1404431
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact