Purpose. To describe an innovative imaging technique to obtain high-quality near-infrared autofluorescence (NIA) images. Methods. Simultaneous fluorescein angiography + indocyanine green angiography (FA + ICGA) acquisition mode (without dye injection) of Spectralis HRA + OCT (Heidelberg Retina Angiograph; Heidelberg Engineering, Heidelberg, Germany), setting maximum level of illuminance, and Automatic Real-time (ART) Module (Heidelberg Engineering) to increase signal-to-noise ratio. Results. The combined confocal scanning laser ophthalmoscope technique allows the Spectralis HRA + OCT device to create high-quality NIA ART images. Conclusions. This innovative imaging technique, consisting of simultaneous FA + ICGA acquisition mode, setting maximum level of illuminance, and ART, allows the Spectralis HRA + OCT device to create high-quality NIA ART images, without requiring the need for the HRA2 (Heidelberg Retina Angiograph; Heidelberg Engineering) device.
Combined Angiography for High-Quality Near-Infrared Autofluorescence Images / Querques, G., Souied, E.h.. - In: OPTOMETRY AND VISION SCIENCE. - ISSN 1040-5488. - 91:1(2014), pp. E9-E13.
Combined Angiography for High-Quality Near-Infrared Autofluorescence Images
QUERQUES , GIUSEPPE;
2014
Abstract
Purpose. To describe an innovative imaging technique to obtain high-quality near-infrared autofluorescence (NIA) images. Methods. Simultaneous fluorescein angiography + indocyanine green angiography (FA + ICGA) acquisition mode (without dye injection) of Spectralis HRA + OCT (Heidelberg Retina Angiograph; Heidelberg Engineering, Heidelberg, Germany), setting maximum level of illuminance, and Automatic Real-time (ART) Module (Heidelberg Engineering) to increase signal-to-noise ratio. Results. The combined confocal scanning laser ophthalmoscope technique allows the Spectralis HRA + OCT device to create high-quality NIA ART images. Conclusions. This innovative imaging technique, consisting of simultaneous FA + ICGA acquisition mode, setting maximum level of illuminance, and ART, allows the Spectralis HRA + OCT device to create high-quality NIA ART images, without requiring the need for the HRA2 (Heidelberg Retina Angiograph; Heidelberg Engineering) device.Pubblicazioni consigliate

I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris