BackgroundRecent evidence documented that dialyzers and hemodialytic techniques yield different dialytic performances. The study aims to compare uremic toxins removal and iron status between on-line hemodiafiltration (OL-HDF), high-flux hemodialysis (HF-HD), expanded hemodialysis (HDx), and HFR Aequilibrium (HFR-Aeq).MethodsA single-center retrospective observational study enrolled 52 patients on chronic HD. Each study group (HFR-Aeq, HDx, HF-HD, and OL-HDF) included 13 patients. Na & iuml;ve patients for each of the treatments were considered. Serum samples were collected at baseline and after 12-24-48 weeks from the enrollment. Intragroup comparison was performed using Friedman's test whereas longitudinal data were compared using linear mixed models (LMMs).ResultsHDx showed a progressive improvement in the removal of urea (p = 0.043), lambda -free light chains (p = 0.033), and transferrin saturation (p = 0.011) compared to other techniques. A nearly significant slope of beta 2 M was observed (p = 0.066). Also HFR-Aeq showed a near significant reduction in lambda FLC values (p = 0.05) and a nearly significant increase in albumin levels (p = 0.07).ConclusionsHFR-Aeq provides uremic toxins removal comparable to other traditional techniques (HF-HD, OL-HDF). HDx confirmed its superiority in the removal of uremic toxins as urea and lambda FLC and surprisingly enhanced TSAT by a possible anti-inflammatory effect not ascertained in the present study. The utilization of non-optimal convective volumes likely vanishes the promising findings of OL-HDF.

Uremic toxins removal and iron status: a medium-term comparison between 4 dialysis techniques (EMPIRE study) / Napoli, M.; Alfano, G.; Scrivo, A.; Zappulo, F.; Morisi, N.; Martano, L.; Giovanella, S.; Ferrarini, M.; La Manna, G.; Donati, G.. - In: RENAL FAILURE. - ISSN 0886-022X. - 47:1(2025), pp. 1-9. [10.1080/0886022X.2025.2497491]

Uremic toxins removal and iron status: a medium-term comparison between 4 dialysis techniques (EMPIRE study)

Alfano G.;Morisi N.;Giovanella S.;Ferrarini M.;Donati G.
2025

Abstract

BackgroundRecent evidence documented that dialyzers and hemodialytic techniques yield different dialytic performances. The study aims to compare uremic toxins removal and iron status between on-line hemodiafiltration (OL-HDF), high-flux hemodialysis (HF-HD), expanded hemodialysis (HDx), and HFR Aequilibrium (HFR-Aeq).MethodsA single-center retrospective observational study enrolled 52 patients on chronic HD. Each study group (HFR-Aeq, HDx, HF-HD, and OL-HDF) included 13 patients. Na & iuml;ve patients for each of the treatments were considered. Serum samples were collected at baseline and after 12-24-48 weeks from the enrollment. Intragroup comparison was performed using Friedman's test whereas longitudinal data were compared using linear mixed models (LMMs).ResultsHDx showed a progressive improvement in the removal of urea (p = 0.043), lambda -free light chains (p = 0.033), and transferrin saturation (p = 0.011) compared to other techniques. A nearly significant slope of beta 2 M was observed (p = 0.066). Also HFR-Aeq showed a near significant reduction in lambda FLC values (p = 0.05) and a nearly significant increase in albumin levels (p = 0.07).ConclusionsHFR-Aeq provides uremic toxins removal comparable to other traditional techniques (HF-HD, OL-HDF). HDx confirmed its superiority in the removal of uremic toxins as urea and lambda FLC and surprisingly enhanced TSAT by a possible anti-inflammatory effect not ascertained in the present study. The utilization of non-optimal convective volumes likely vanishes the promising findings of OL-HDF.
2025
47
1
1
9
Uremic toxins removal and iron status: a medium-term comparison between 4 dialysis techniques (EMPIRE study) / Napoli, M.; Alfano, G.; Scrivo, A.; Zappulo, F.; Morisi, N.; Martano, L.; Giovanella, S.; Ferrarini, M.; La Manna, G.; Donati, G.. - In: RENAL FAILURE. - ISSN 0886-022X. - 47:1(2025), pp. 1-9. [10.1080/0886022X.2025.2497491]
Napoli, M.; Alfano, G.; Scrivo, A.; Zappulo, F.; Morisi, N.; Martano, L.; Giovanella, S.; Ferrarini, M.; La Manna, G.; Donati, G.
File in questo prodotto:
File Dimensione Formato  
Uremic toxins removal and iron status a medium-term comparison between 4 dialysis techniques EMPIRE study .pdf

Accesso riservato

Tipologia: VOR - Versione pubblicata dall'editore
Dimensione 1.45 MB
Formato Adobe PDF
1.45 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1378188
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact