Objective: To investigate outcomes of an off the shelf pre-loaded inner branched endograft (E-nside) for the treatment of juxtarenal and pararenal abdominal aortic aneurysms (JP-AAAs). Methods: Data from a multicentre registry (INBREED), including patients treated with the E-nside endograft, were collected and analysed prospectively. Patients treated for JP-AAA were included. Pre-operative clinical and anatomical characteristics, procedural data, and 30 day and one year outcomes were recorded. Endpoints were technical success, 30 day death, major adverse events (MAEs), and one year freedom from target vessel instability. Results: Of 185 consecutively treated patients, 47 (25.4%) had a JP-AAA (juxtarenal n = 10, 21%; pararenal n = 37, 79%) and were included in the study; 183 target vessels were incorporated through an inner branch. Procedural setting was emergency or urgent in 18 patients (38%) owing to a contained aortic rupture (n = 2, 4%), symptomatic aneurysm (n = 4, 9%), or aneurysm > 70 mm (n = 12, 26%). The mean length of aortic coverage above the coeliac trunk was 116 ± 7 mm. Technical success was 100% and 30 day mortality rate 4% (n = 2 urgent cases). The 30 day cumulative MAE rate was 26% (n = 12): two stroke (4%); and seven spinal cord ischaemia (15%), with six in an elective setting (21%) and one in an urgent setting (6%), and five leading to permanent paraplegia or paraparesis (10%). Freedom from target vessel instability was 99% after 30 days and 97 ± 3% after one year. Conclusion: Use of an off the shelf inner branched device for treating JP-AAA was feasible in urgent and elective settings, with high technical success and satisfactory target vessel stability at one year. In the treatment of JP-AAA, stroke and spinal cord ischaemia may be associated with arm access and the increased aortic coverage that the design brings.
Use of an Off the Shelf Inner Branch Thoraco-abdominal Endograft for the Treatment of Juxtarenal and Pararenal Aortic Aneurysms / Squizzato, F.; Piazza, M.; Isernia, G.; Pratesi, G.; Gatta, E.; Ferri, M.; Tshomba, Y.; Gattuso, R.; Veraldi, G. F.; Antonello, M.; Piazza, M.; Squizzato, F.; Spezia, M.; Spinella, G.; Esposito, D.; Bastianon, M.; Tshomba, Y.; Donati, T.; Sica, S.; Tinelli, G.; Quaglino, S.; Gaggiano, A.; Vento, V.; Carbonari, L.; Lenti, M.; Simonte, G.; Parlani, G.; Piffaretti, G.; Frigatti, P.; Scrivere, P.; Furlan, F.; Mezzetto, L.; Gennai, S.; Leone, N.; Silingardi, R.; Iacono, G.; Turricchia, G. U.; Angiletta, D.; Maione, M.; Apostolou, D.; Pulli, R.; Fargion, A.; Filippi, F.; De Angelis, F.; Arici, V.; Bozzani, A.; Luigi Molinari, A. C.; Rossi, G.; Brancadoro, E. C.; Ferraris, M.; Dorrucci, V.; Derone, G.; Tolva, V. S.; Compagnoni, N. M.; Segramora, V. M.; Deleo, G.; Bracale, U.; Turchino, D.; Guzzardi, G.; Ferrer, C.; Giudice, R.; Sbarigia, E.; Cuozzo, S.; Gattuso, R.; Mansour, W.; Di Marzo, L.; Grimaldi, S.; Corona, M.; Chisci, E.; Mechelagnoli, S.; De Donato, G.; Palasciano, G.; Pasqui, E.; Candeloro, L.; Ricci, C.; Neri, E.; Mangialardi, N.; Orrico, M.; Ronchey, S.; Fazzini, S.; Ippoliti, A.; Discalzi, A.; Rossato, D.; Vio, E.; Galeazzi, E.; Farneti, F.; Bonardelli, S.; Bertoglio, L.; Melloni, A.; Grandi, A.; Volpe, P.; Massara, M.; Milite, D.; Xodo, A.. - In: EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY. - ISSN 1078-5884. - (2025), pp. 0-9. [10.1016/j.ejvs.2025.02.030]
Use of an Off the Shelf Inner Branch Thoraco-abdominal Endograft for the Treatment of Juxtarenal and Pararenal Aortic Aneurysms
Gennai S.;Leone N.;Silingardi R.;
2025
Abstract
Objective: To investigate outcomes of an off the shelf pre-loaded inner branched endograft (E-nside) for the treatment of juxtarenal and pararenal abdominal aortic aneurysms (JP-AAAs). Methods: Data from a multicentre registry (INBREED), including patients treated with the E-nside endograft, were collected and analysed prospectively. Patients treated for JP-AAA were included. Pre-operative clinical and anatomical characteristics, procedural data, and 30 day and one year outcomes were recorded. Endpoints were technical success, 30 day death, major adverse events (MAEs), and one year freedom from target vessel instability. Results: Of 185 consecutively treated patients, 47 (25.4%) had a JP-AAA (juxtarenal n = 10, 21%; pararenal n = 37, 79%) and were included in the study; 183 target vessels were incorporated through an inner branch. Procedural setting was emergency or urgent in 18 patients (38%) owing to a contained aortic rupture (n = 2, 4%), symptomatic aneurysm (n = 4, 9%), or aneurysm > 70 mm (n = 12, 26%). The mean length of aortic coverage above the coeliac trunk was 116 ± 7 mm. Technical success was 100% and 30 day mortality rate 4% (n = 2 urgent cases). The 30 day cumulative MAE rate was 26% (n = 12): two stroke (4%); and seven spinal cord ischaemia (15%), with six in an elective setting (21%) and one in an urgent setting (6%), and five leading to permanent paraplegia or paraparesis (10%). Freedom from target vessel instability was 99% after 30 days and 97 ± 3% after one year. Conclusion: Use of an off the shelf inner branched device for treating JP-AAA was feasible in urgent and elective settings, with high technical success and satisfactory target vessel stability at one year. In the treatment of JP-AAA, stroke and spinal cord ischaemia may be associated with arm access and the increased aortic coverage that the design brings.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S1078588425001649-main.pdf
Open access
Tipologia:
VOR - Versione pubblicata dall'editore
Dimensione
854.32 kB
Formato
Adobe PDF
|
854.32 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris