The deck expansion devices installed at the abutment can be eliminated by using the concept of the semi-integral abutment bridge (SIAB) to improve the serviceability and durability of the bridge. The mechanical performance of the girders in the SIABs with continuous structure or continuous deck between adjacent girders could be different. To investigate the different response of the two bridge typologies, a SIAB built in China was chosen as a case study. A finite element model (FEM) established by using the MIDAS-Civil software was used to compare the mechanical performance of the continuous structure SIAB or continuous beck SIAB under different load cases. The influence of different girder connection types and bridge lengths on the mechanical performance of a multi-span SIAB was studied. The results showed that the influence of the girder connection types on the internal force of the girder of a two-span SIAB is significant. Compared with the continuous structure SIAB, the absolute bending moments of the girder at the pier top, end diaphragm and mid span of the girder in continuous deck SIAB are lower, however, the shear forces of the girder at the pier top and end diaphragm are higher. With an increase in the bridge length, the continuous structure SIAB is more sensitive to the temperature variation than the continuous deck SIAB. The maximum lengths of the multi-span continuous structure SIAB and the multi-span continuous deck SIAB is 26 m (two-span) and 52 m (four-span), respectively.
Influence of Girder Connection Type on Mechanical Performance of Multispan Semi-integral Abutment Bridge / Briseghella, B.; Shi, J.; Xue, J.; Huang, F.; Miao, J.; Wang, X.. - (2023), pp. 221-228. (Intervento presentato al convegno IABSE Symposium Istanbul 2023: Long Span Bridges tenutosi a Hyatt Regency Istanbul Atakoy Hotel, tur nel 2023).
Influence of Girder Connection Type on Mechanical Performance of Multispan Semi-integral Abutment Bridge
Briseghella B.;
2023
Abstract
The deck expansion devices installed at the abutment can be eliminated by using the concept of the semi-integral abutment bridge (SIAB) to improve the serviceability and durability of the bridge. The mechanical performance of the girders in the SIABs with continuous structure or continuous deck between adjacent girders could be different. To investigate the different response of the two bridge typologies, a SIAB built in China was chosen as a case study. A finite element model (FEM) established by using the MIDAS-Civil software was used to compare the mechanical performance of the continuous structure SIAB or continuous beck SIAB under different load cases. The influence of different girder connection types and bridge lengths on the mechanical performance of a multi-span SIAB was studied. The results showed that the influence of the girder connection types on the internal force of the girder of a two-span SIAB is significant. Compared with the continuous structure SIAB, the absolute bending moments of the girder at the pier top, end diaphragm and mid span of the girder in continuous deck SIAB are lower, however, the shear forces of the girder at the pier top and end diaphragm are higher. With an increase in the bridge length, the continuous structure SIAB is more sensitive to the temperature variation than the continuous deck SIAB. The maximum lengths of the multi-span continuous structure SIAB and the multi-span continuous deck SIAB is 26 m (two-span) and 52 m (four-span), respectively.Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris