The ratio between arterial blood partial pressure of oxygen and fraction of inspired oxygen (PaO2/FiO2) was largely used for grading and managing the respiratory failure in non-mechanically ventilated COVID-19. In these patients, the assessment of the true FiO2 in the inspired mixture may be difficult with consequent inaccuracies in PaO2/FiO2 assessment. In 30 severe COVID-19 patients, we observed that PaO2/FiO2 values measured immediately before and after the transition from high-flow nasal cannula (HFNC) to one commercially available Venturi mask O2 therapy were similar (bias mean value 0, standard deviation 23 mmHg). In COVID-19 patients recovering from respiratory failure, PaO2/FiO2 is not different whether measured with a commercially available Venturi mask or HFNC.

Difference in PaO2/FiO2 between high-flow nasal cannula and Venturi mask in hypoxemic COVID-19 patients / Gatto, I.; Biagioni, E.; Coloretti, I.; Viappiani, S.; Busani, S.; Girardis, M.. - In: JOURNAL OF ANESTHESIA, ANALGESIA AND CRITICAL CARE. - ISSN 2731-3786. - 2:1(2022), pp. 1-3. [10.1186/s44158-022-00051-w]

Difference in PaO2/FiO2 between high-flow nasal cannula and Venturi mask in hypoxemic COVID-19 patients

Gatto I.;Biagioni E.;Coloretti I.;Busani S.;Girardis M.
2022

Abstract

The ratio between arterial blood partial pressure of oxygen and fraction of inspired oxygen (PaO2/FiO2) was largely used for grading and managing the respiratory failure in non-mechanically ventilated COVID-19. In these patients, the assessment of the true FiO2 in the inspired mixture may be difficult with consequent inaccuracies in PaO2/FiO2 assessment. In 30 severe COVID-19 patients, we observed that PaO2/FiO2 values measured immediately before and after the transition from high-flow nasal cannula (HFNC) to one commercially available Venturi mask O2 therapy were similar (bias mean value 0, standard deviation 23 mmHg). In COVID-19 patients recovering from respiratory failure, PaO2/FiO2 is not different whether measured with a commercially available Venturi mask or HFNC.
2022
2
1
1
3
Difference in PaO2/FiO2 between high-flow nasal cannula and Venturi mask in hypoxemic COVID-19 patients / Gatto, I.; Biagioni, E.; Coloretti, I.; Viappiani, S.; Busani, S.; Girardis, M.. - In: JOURNAL OF ANESTHESIA, ANALGESIA AND CRITICAL CARE. - ISSN 2731-3786. - 2:1(2022), pp. 1-3. [10.1186/s44158-022-00051-w]
Gatto, I.; Biagioni, E.; Coloretti, I.; Viappiani, S.; Busani, S.; Girardis, M.
File in questo prodotto:
File Dimensione Formato  
GattoDifferenceP:FJACC2022.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 735.69 kB
Formato Adobe PDF
735.69 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1350307
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact