A subcutaneous, prepectoral, muscle-sparing approach has been recently described for implant-based breast reconstruction. This is a preliminary series of 2-stage breast reconstructions by means of tissue expander placed subcutaneously with the support of a titanium-coated polypropylene mesh. A pilot series of cases was started in 2012. Inclusion criteria were informed consent, age less than 80 years, normal body mass index (range, 18.5-24.9), no T4 and metastatic cancers, no comorbidities, and nonsmoking patients. Expander losses, infections, seromas, skin/nipple necrosis, wound dehiscence, and reinterventions were registered in follow-up visits. Furthermore, patients were followed up in second-stage procedures and for at least 1 year from implant positioning to collect any surgical complication, reinterventions, cosmetic outcome, and oncological data. Between June 2012 and March 2014, 25 cases were enrolled in the study. Expander/implant loss rate was 0%. Skin/nipple necrosis rate was 4%. Infections rate was 12% after first-stage and 4% after second-stage procedure. Seromas rate was 0%. Five (20%) fat graft procedures were performed over the expander before second-stage reconstruction, and no reinterventions were required after second stage. Patients mean score was 99 for cosmetic outcome satisfaction, in a 0-100 scale. Subcutaneous 2-stage reconstruction with synthetic mesh proved safe and feasible. Patients satisfaction is very good after 14 months median follow-up form definitive implant placement. Although the present study involved only a small number of cases, a tissue-expander subcutaneous reconstruction seems to have promising results. Whenever pectoralis major muscle can be spared, a conservative reconstruction might be an option.
Subcutaneous Tissue Expander Placement with Synthetic Titanium-Coated Mesh in Breast Reconstruction: Long-term Results / Casella, Donato; Calabrese, Claudio; Bianchi, Simonetta; Meattini, Icro; Bernini, Marco. - In: PLASTIC AND RECONSTRUCTIVE SURGERY – GLOBAL OPEN. - ISSN 2169-7574. - 3:12(2016), pp. 0-0. [10.1097/GOX.0000000000000549]
Subcutaneous Tissue Expander Placement with Synthetic Titanium-Coated Mesh in Breast Reconstruction: Long-term Results
BERNINI, MARCO
2016
Abstract
A subcutaneous, prepectoral, muscle-sparing approach has been recently described for implant-based breast reconstruction. This is a preliminary series of 2-stage breast reconstructions by means of tissue expander placed subcutaneously with the support of a titanium-coated polypropylene mesh. A pilot series of cases was started in 2012. Inclusion criteria were informed consent, age less than 80 years, normal body mass index (range, 18.5-24.9), no T4 and metastatic cancers, no comorbidities, and nonsmoking patients. Expander losses, infections, seromas, skin/nipple necrosis, wound dehiscence, and reinterventions were registered in follow-up visits. Furthermore, patients were followed up in second-stage procedures and for at least 1 year from implant positioning to collect any surgical complication, reinterventions, cosmetic outcome, and oncological data. Between June 2012 and March 2014, 25 cases were enrolled in the study. Expander/implant loss rate was 0%. Skin/nipple necrosis rate was 4%. Infections rate was 12% after first-stage and 4% after second-stage procedure. Seromas rate was 0%. Five (20%) fat graft procedures were performed over the expander before second-stage reconstruction, and no reinterventions were required after second stage. Patients mean score was 99 for cosmetic outcome satisfaction, in a 0-100 scale. Subcutaneous 2-stage reconstruction with synthetic mesh proved safe and feasible. Patients satisfaction is very good after 14 months median follow-up form definitive implant placement. Although the present study involved only a small number of cases, a tissue-expander subcutaneous reconstruction seems to have promising results. Whenever pectoralis major muscle can be spared, a conservative reconstruction might be an option.File | Dimensione | Formato | |
---|---|---|---|
Casella et al 2016.pdf
Open access
Tipologia:
VOR - Versione pubblicata dall'editore
Dimensione
682.73 kB
Formato
Adobe PDF
|
682.73 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris