Aims: Remote monitoring (RM) is the standard of care for follow up of patients with cardiac implantable electronic devices. The aim of this study was to compare smartphone-based RM (SM-RM) using patient applications (myMerlinPulse™ app) with traditional bedside monitor RM (BM-RM). Methods and results: The retrospective study included de-identified US patients who received either SM-RM or BM-RM capable of implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators (Abbott, USA). Patients in SM-RM and BM-RM groups were propensity-score matched on age and gender, device type, implant year, and month. Compliance with RM was quantified as the proportion of patients enrolling in the RM system (Merlin.net™) and transmitting data at least once. Connectivity was measured by the median number of days between consecutive transmissions per patient. Of the initial 9714 patients with SM-RM and 26 679 patients with BM-RM, 9397 patients from each group were matched. Remote monitoring compliance was higher in SM-RM; significantly more patients with SM-RM were enrolled in RM compared with BM-RM (94.4 vs. 85.0%, P < 0.001), similar number of patients in the SM-RM group paired their device (95.1 vs. 95.0%, P = 0.77), but more SM-RM patients transmitted at least once (98.1 vs. 94.3%, P < 0.001). Connectivity was significantly higher in the SM-RM, with patients transmitting data every 1.2 (1.1, 1.7) vs. every 1.7 (1.5, 2.0) days with BM-RM (P < 0.001) and remained better over time. Significantly more SM-RM patients utilized patient-initiated transmissions compared with BM-RM (55.6 vs. 28.1%, P < 0.001). Conclusion: In this large real-world study, patients with SM-RM demonstrated improved compliance and connectivity compared with BM-RM.

Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity / Manyam, H.; Burri, H.; Casado-Arroyo, R.; Varma, N.; Lennerz, C.; Klug, D.; Carr-White, G.; Kolli, K.; Reyes, I.; Nabutovsky, Y.; Boriani, G.. - In: EUROPEAN HEART JOURNAL. DIGITAL HEALTH. - ISSN 2634-3916. - 4:1(2023), pp. 43-52. [10.1093/ehjdh/ztac071]

Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity

Boriani G.
2023

Abstract

Aims: Remote monitoring (RM) is the standard of care for follow up of patients with cardiac implantable electronic devices. The aim of this study was to compare smartphone-based RM (SM-RM) using patient applications (myMerlinPulse™ app) with traditional bedside monitor RM (BM-RM). Methods and results: The retrospective study included de-identified US patients who received either SM-RM or BM-RM capable of implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators (Abbott, USA). Patients in SM-RM and BM-RM groups were propensity-score matched on age and gender, device type, implant year, and month. Compliance with RM was quantified as the proportion of patients enrolling in the RM system (Merlin.net™) and transmitting data at least once. Connectivity was measured by the median number of days between consecutive transmissions per patient. Of the initial 9714 patients with SM-RM and 26 679 patients with BM-RM, 9397 patients from each group were matched. Remote monitoring compliance was higher in SM-RM; significantly more patients with SM-RM were enrolled in RM compared with BM-RM (94.4 vs. 85.0%, P < 0.001), similar number of patients in the SM-RM group paired their device (95.1 vs. 95.0%, P = 0.77), but more SM-RM patients transmitted at least once (98.1 vs. 94.3%, P < 0.001). Connectivity was significantly higher in the SM-RM, with patients transmitting data every 1.2 (1.1, 1.7) vs. every 1.7 (1.5, 2.0) days with BM-RM (P < 0.001) and remained better over time. Significantly more SM-RM patients utilized patient-initiated transmissions compared with BM-RM (55.6 vs. 28.1%, P < 0.001). Conclusion: In this large real-world study, patients with SM-RM demonstrated improved compliance and connectivity compared with BM-RM.
2023
4
1
43
52
Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity / Manyam, H.; Burri, H.; Casado-Arroyo, R.; Varma, N.; Lennerz, C.; Klug, D.; Carr-White, G.; Kolli, K.; Reyes, I.; Nabutovsky, Y.; Boriani, G.. - In: EUROPEAN HEART JOURNAL. DIGITAL HEALTH. - ISSN 2634-3916. - 4:1(2023), pp. 43-52. [10.1093/ehjdh/ztac071]
Manyam, H.; Burri, H.; Casado-Arroyo, R.; Varma, N.; Lennerz, C.; Klug, D.; Carr-White, G.; Kolli, K.; Reyes, I.; Nabutovsky, Y.; Boriani, G.
File in questo prodotto:
File Dimensione Formato  
ztac071.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 825.6 kB
Formato Adobe PDF
825.6 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1322407
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact