AIMS: Electrophysiological (EP) operations that have traditionally involved long hospital lengths of stay (LOS) are now being undertaken as day case procedures. The coronavirus disease-19 pandemic served as an impetus for many centres to shorten LOS for EP procedures. This survey explores LOS for elective EP procedures in the modern era. METHODS AND RESULTS: An online survey consisting of 27 multiple-choice questions was completed by 245 respondents from 35 countries. With respect to de novo cardiac implantable electronic device (CIED) implantations, day case procedures were reported for 79.5% of implantable loop recorders, 13.3% of pacemakers (PMs), 10.4% of implantable cardioverter defibrillators (ICDs), and 10.2% of cardiac resynchronization therapy (CRT) devices. With respect to CIED generator replacements, day case procedures were reported for 61.7% of PMs, 49.2% of ICDs, and 48.2% of CRT devices. With regard to ablations, day case procedures were reported for 5.7% of atrial fibrillation (AF) ablations, 10.7% of left-sided ablations, and 17.5% of right-sided ablations. A LOS ≥ 2 days for CIED implantation was reported for 47.7% of PM, 54.5% of ICDs, and 56.9% of CRT devices and for 54.5% of AF ablations, 42.2% of right-sided ablations, and 46.1% of left-sided ablations. Reimbursement (43-56%) and bed availability (20-47%) were reported to have no consistent impact on the organization of elective procedures. CONCLUSION: There is a wide variation in the LOS for elective EP procedures. The LOS for some procedures appears disproportionate to their complexity. Neither reimbursement nor bed availability consistently influenced LOS.

Length of hospital stay for elective electrophysiological procedures: a survey from the European Heart Rhythm Association / Boriani, G.; Imberti, J. F.; Leyva, F.; Casado-Arroyo, R.; Chun, J.; Braunschweig, F.; Zylla, M. M.; Duncker, D.; Farkowski, M. M.; Purerfellner, H.; Merino, J. L.. - In: EUROPACE. - ISSN 1532-2092. - 25:10(2023), pp. N/A-N/A. [10.1093/europace/euad297]

Length of hospital stay for elective electrophysiological procedures: a survey from the European Heart Rhythm Association

Boriani G.;Imberti J. F.;
2023

Abstract

AIMS: Electrophysiological (EP) operations that have traditionally involved long hospital lengths of stay (LOS) are now being undertaken as day case procedures. The coronavirus disease-19 pandemic served as an impetus for many centres to shorten LOS for EP procedures. This survey explores LOS for elective EP procedures in the modern era. METHODS AND RESULTS: An online survey consisting of 27 multiple-choice questions was completed by 245 respondents from 35 countries. With respect to de novo cardiac implantable electronic device (CIED) implantations, day case procedures were reported for 79.5% of implantable loop recorders, 13.3% of pacemakers (PMs), 10.4% of implantable cardioverter defibrillators (ICDs), and 10.2% of cardiac resynchronization therapy (CRT) devices. With respect to CIED generator replacements, day case procedures were reported for 61.7% of PMs, 49.2% of ICDs, and 48.2% of CRT devices. With regard to ablations, day case procedures were reported for 5.7% of atrial fibrillation (AF) ablations, 10.7% of left-sided ablations, and 17.5% of right-sided ablations. A LOS ≥ 2 days for CIED implantation was reported for 47.7% of PM, 54.5% of ICDs, and 56.9% of CRT devices and for 54.5% of AF ablations, 42.2% of right-sided ablations, and 46.1% of left-sided ablations. Reimbursement (43-56%) and bed availability (20-47%) were reported to have no consistent impact on the organization of elective procedures. CONCLUSION: There is a wide variation in the LOS for elective EP procedures. The LOS for some procedures appears disproportionate to their complexity. Neither reimbursement nor bed availability consistently influenced LOS.
2023
25
10
N/A
N/A
Length of hospital stay for elective electrophysiological procedures: a survey from the European Heart Rhythm Association / Boriani, G.; Imberti, J. F.; Leyva, F.; Casado-Arroyo, R.; Chun, J.; Braunschweig, F.; Zylla, M. M.; Duncker, D.; Farkowski, M. M.; Purerfellner, H.; Merino, J. L.. - In: EUROPACE. - ISSN 1532-2092. - 25:10(2023), pp. N/A-N/A. [10.1093/europace/euad297]
Boriani, G.; Imberti, J. F.; Leyva, F.; Casado-Arroyo, R.; Chun, J.; Braunschweig, F.; Zylla, M. M.; Duncker, D.; Farkowski, M. M.; Purerfellner, H.; Merino, J. L.
File in questo prodotto:
File Dimensione Formato  
euad297.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 457.65 kB
Formato Adobe PDF
457.65 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1322402
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact