Background: The HeartLogic algorithm (Boston Scientific) has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation. Objective: The purpose of this study was to determine whether remotely monitored data from this algorithm could be used to identify patients at high risk for mortality. Methods: The algorithm combines implantable cardioverter-defibrillator (ICD)–measured accelerometer-based heart sounds, intrathoracic impedance, respiration rate, ratio of respiration rate to tidal volume, night heart rate, and patient activity into a single index. An alert is issued when the index crosses a programmable threshold. The feature was activated in 568 ICD patients from 26 centers. Results: During median follow-up of 26 months [25th–75th percentile 16–37], 1200 alerts were recorded in 370 patients (65%). Overall, the time IN-alert state was 13% of the total observation period (151/1159 years) and 20% of the follow-up period of the 370 patients with alerts. During follow-up, 55 patients died (46 in the group with alerts). The rate of death was 0.25 per patient-year (95% confidence interval [CI] 0.17–0.34) IN-alert state and 0.02 per patient-year (95% CI 0.01–0.03) OUT of the alert state, with an incidence rate ratio of 13.72 (95% CI 7.62–25.60; P <.001). After multivariate correction for baseline confounders (age, ischemic cardiomyopathy, kidney disease, atrial fibrillation), the IN-alert state remained significantly associated with the occurrence of death (hazard ratio 9.18; 95% CI 5.27–15.99; P <.001). Conclusion: The HeartLogic algorithm provides an index that can be used to identify patients at higher risk for all-cause mortality. The index state identifies periods of significantly increased risk of death.

Predicting all-cause mortality by means of a multisensor implantable defibrillator algorithm for heart failure monitoring / D'Onofrio, A., Vitulano, G., Calo, L., Bertini, M., Santini, L., Savarese, G., Dello Russo, A., Santobuono, V.E., Lavalle, C., Viscusi, M., Amellone, C., Calvanese, R., Santoro, A., Ziacchi, M., Palmisano, P., Pisano, E., Bianchi, V., Tavoletta, V., Campari, M., Valsecchi, S., et al.. - In: HEART RHYTHM. - ISSN 1547-5271. - 20:7(2023), pp. 992-997. [10.1016/j.hrthm.2023.03.026]

Predicting all-cause mortality by means of a multisensor implantable defibrillator algorithm for heart failure monitoring

Bianchi V.;Boriani G.
2023

Abstract

Background: The HeartLogic algorithm (Boston Scientific) has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation. Objective: The purpose of this study was to determine whether remotely monitored data from this algorithm could be used to identify patients at high risk for mortality. Methods: The algorithm combines implantable cardioverter-defibrillator (ICD)–measured accelerometer-based heart sounds, intrathoracic impedance, respiration rate, ratio of respiration rate to tidal volume, night heart rate, and patient activity into a single index. An alert is issued when the index crosses a programmable threshold. The feature was activated in 568 ICD patients from 26 centers. Results: During median follow-up of 26 months [25th–75th percentile 16–37], 1200 alerts were recorded in 370 patients (65%). Overall, the time IN-alert state was 13% of the total observation period (151/1159 years) and 20% of the follow-up period of the 370 patients with alerts. During follow-up, 55 patients died (46 in the group with alerts). The rate of death was 0.25 per patient-year (95% confidence interval [CI] 0.17–0.34) IN-alert state and 0.02 per patient-year (95% CI 0.01–0.03) OUT of the alert state, with an incidence rate ratio of 13.72 (95% CI 7.62–25.60; P <.001). After multivariate correction for baseline confounders (age, ischemic cardiomyopathy, kidney disease, atrial fibrillation), the IN-alert state remained significantly associated with the occurrence of death (hazard ratio 9.18; 95% CI 5.27–15.99; P <.001). Conclusion: The HeartLogic algorithm provides an index that can be used to identify patients at higher risk for all-cause mortality. The index state identifies periods of significantly increased risk of death.
2023
20
7
992
997
Predicting all-cause mortality by means of a multisensor implantable defibrillator algorithm for heart failure monitoring / D'Onofrio, A., Vitulano, G., Calo, L., Bertini, M., Santini, L., Savarese, G., Dello Russo, A., Santobuono, V.E., Lavalle, C., Viscusi, M., Amellone, C., Calvanese, R., Santoro, A., Ziacchi, M., Palmisano, P., Pisano, E., Bianchi, V., Tavoletta, V., Campari, M., Valsecchi, S., et al.. - In: HEART RHYTHM. - ISSN 1547-5271. - 20:7(2023), pp. 992-997. [10.1016/j.hrthm.2023.03.026]
D'Onofrio, A.; Vitulano, G.; Calo, L.; Bertini, M.; Santini, L.; Savarese, G.; Dello Russo, A.; Santobuono, V. E.; Lavalle, C.; Viscusi, M.; Amellone,...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1322395
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 8
social impact