In this paper, we describe how using a liquid lens can improve the quality of iris images acquired by a hyperspectral system. This improvement in the image quality is especially noticeable for systems that scan the iris over a wide range of wavelengths, e.g. visible and near-infrared spectrum. We have tested this approach on the previously developed system able to acquire iris images in the spectral range 480 - 900 nm. The key novelty presented in this paper is represented by the possibility of adaptively adjusting the focus of the imaging system, allowing for chromatic aberration compensation and ensuring a constant image sharpness among all wavelengths. A fast-tunable liquid lens has been placed in front of the chromatically corrected camera objective to adaptively change the overall focus of the imaging system. The findings imply that the device can rapidly perform hyperspectral measurements of the iris over a broad wavelength range ensuring optimal focus for all images.

On the use of a liquid lens for improving iris images quality in a hyperspectral system / Masetti, Ettore; Rovati, Luigi. - In: PROGRESS IN BIOMEDICAL OPTICS AND IMAGING. - ISSN 1605-7422. - 12360:(2023), p. 64. (Intervento presentato al convegno SPIE Photonics West - BIOS tenutosi a San Francisco, California, U.S.A. nel 31/01/2023) [10.1117/12.2650233].

On the use of a liquid lens for improving iris images quality in a hyperspectral system

Masetti, Ettore
;
Rovati, Luigi
2023

Abstract

In this paper, we describe how using a liquid lens can improve the quality of iris images acquired by a hyperspectral system. This improvement in the image quality is especially noticeable for systems that scan the iris over a wide range of wavelengths, e.g. visible and near-infrared spectrum. We have tested this approach on the previously developed system able to acquire iris images in the spectral range 480 - 900 nm. The key novelty presented in this paper is represented by the possibility of adaptively adjusting the focus of the imaging system, allowing for chromatic aberration compensation and ensuring a constant image sharpness among all wavelengths. A fast-tunable liquid lens has been placed in front of the chromatically corrected camera objective to adaptively change the overall focus of the imaging system. The findings imply that the device can rapidly perform hyperspectral measurements of the iris over a broad wavelength range ensuring optimal focus for all images.
2023
SPIE Photonics West - BIOS
San Francisco, California, U.S.A.
31/01/2023
12360
64
Masetti, Ettore; Rovati, Luigi
On the use of a liquid lens for improving iris images quality in a hyperspectral system / Masetti, Ettore; Rovati, Luigi. - In: PROGRESS IN BIOMEDICAL OPTICS AND IMAGING. - ISSN 1605-7422. - 12360:(2023), p. 64. (Intervento presentato al convegno SPIE Photonics West - BIOS tenutosi a San Francisco, California, U.S.A. nel 31/01/2023) [10.1117/12.2650233].
File in questo prodotto:
File Dimensione Formato  
123600K.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 981.9 kB
Formato Adobe PDF
981.9 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1300486
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact