IntroductionVDD pacing system was introduced more than 30 years ago. Its use is considered by the 2021 European Society of Cardiology guidelines on cardiac pacing as a potential alternative to dual chambers system for patients with atrioventricular block and normal sinus node function.Areas coveredIn this article, we performed a narrative review of current literature in order to identify the strengths and weaknesses of this pacing system. VDD system allows the maintenance of AV synchronous pacing and its hemodynamic advantages. Some disadvantages may be related to the non-negligible incidence of atrial undersensing and the possible subsequent need for upgrade to DDD system. On the other hand, shorter implantation time and lower complications rate may be advantages.Expert opinionIn the modern pacing era, VDD pacing system struggles to find its own space. However, it may still be considered as a valuable alternative to a dual-chamber pacemaker for selected patients, in specific clinical scenarios.

Single-lead VDD pacing: a literature review on short-term and long-term performance / Mei, Davide Antonio; Imberti, Jacopo Francesco; Vitolo, Marco; Bonini, Niccolò; Gerra, Luigi; Romiti, Giulio Francesco; Proietti, Marco; Lip, Gregory Y H; Boriani, Giuseppe. - In: EXPERT REVIEW OF MEDICAL DEVICES. - ISSN 1743-4440. - 20:3(2023), pp. N/A-N/A. [10.1080/17434440.2023.2178901]

Single-lead VDD pacing: a literature review on short-term and long-term performance

Mei, Davide Antonio;Imberti, Jacopo Francesco;Vitolo, Marco;Bonini, Niccolò;Gerra, Luigi;Boriani, Giuseppe
2023

Abstract

IntroductionVDD pacing system was introduced more than 30 years ago. Its use is considered by the 2021 European Society of Cardiology guidelines on cardiac pacing as a potential alternative to dual chambers system for patients with atrioventricular block and normal sinus node function.Areas coveredIn this article, we performed a narrative review of current literature in order to identify the strengths and weaknesses of this pacing system. VDD system allows the maintenance of AV synchronous pacing and its hemodynamic advantages. Some disadvantages may be related to the non-negligible incidence of atrial undersensing and the possible subsequent need for upgrade to DDD system. On the other hand, shorter implantation time and lower complications rate may be advantages.Expert opinionIn the modern pacing era, VDD pacing system struggles to find its own space. However, it may still be considered as a valuable alternative to a dual-chamber pacemaker for selected patients, in specific clinical scenarios.
2023
20
3
N/A
N/A
Single-lead VDD pacing: a literature review on short-term and long-term performance / Mei, Davide Antonio; Imberti, Jacopo Francesco; Vitolo, Marco; Bonini, Niccolò; Gerra, Luigi; Romiti, Giulio Francesco; Proietti, Marco; Lip, Gregory Y H; Boriani, Giuseppe. - In: EXPERT REVIEW OF MEDICAL DEVICES. - ISSN 1743-4440. - 20:3(2023), pp. N/A-N/A. [10.1080/17434440.2023.2178901]
Mei, Davide Antonio; Imberti, Jacopo Francesco; Vitolo, Marco; Bonini, Niccolò; Gerra, Luigi; Romiti, Giulio Francesco; Proietti, Marco; Lip, Gregory ...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1299525
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
social impact