Objectives To evaluate the feasibility of contrast-enhanced mammography (CEM)-guided biopsy at Hospital del Mar, a Spanish university hospital. Methods We retrospectively reviewed all consecutive women with a suspicious enhancing finding eligible for CEM-guided biopsy, who were prospectively enrolled in a pre-marketing clinical validation and feasibility study (October 2019 to September 2021). CEM-guided biopsy is a stereotactic-based procedure that, by using intravenous iodinated contrast media administration and dual-energy acquisition, provides localisation of enhancing lesions. All the biopsies were performed using a vacuum-assisted device. We collected procedural characteristics (patient position and type of approach), and histopathological results. Feasibility endpoints included success (visualisation of the enhancing lesion, post-procedural biopsy changes and clip placement), procedural time, number of scout acquisitions and complications. Results A total of 66 suspicious enhancing lesions (18.0% foci, 44.0% mass, 38.0% non-mass enhancement; median size 8.5 mm) in 64 patients (median age 59 years, mostly minimal [48.4%] or mild [32.8%] background parenchymal enhancement) were referred for CEM-guided biopsy in the study period. The success rate was 63/66 (95.4%). Amongst successful procedures, patients were most frequently seated (52/63, 82.5%) and the preferred approach was horizontal (48/63, 76.2%). Median total time per procedure was 15 min. Median number of acquisitions needed before targeting was 2 (range 1-4). Complications consisted of hematoma (17/63, 27%) and vasovagal reaction (2/63, 3.2%). At histology, the malignancy rate was 25/63 (39.7%). Conclusion In this first patient series, CEM-guided breast biopsy was feasible, with success and complication rates similar to those previously reported for magnetic resonance guidance.

Contrast-enhanced mammography-guided biopsy: technical feasibility and first outcomes / Alcantara, R.; Posso, M.; Pitarch, M.; Arenas, N.; Ejarque, B.; Iotti, V.; Besutti, G.. - In: EUROPEAN RADIOLOGY. - ISSN 1432-1084. - 33:1(2023), pp. 417-428. [10.1007/s00330-022-09021-w]

Contrast-enhanced mammography-guided biopsy: technical feasibility and first outcomes

Besutti G.
2023

Abstract

Objectives To evaluate the feasibility of contrast-enhanced mammography (CEM)-guided biopsy at Hospital del Mar, a Spanish university hospital. Methods We retrospectively reviewed all consecutive women with a suspicious enhancing finding eligible for CEM-guided biopsy, who were prospectively enrolled in a pre-marketing clinical validation and feasibility study (October 2019 to September 2021). CEM-guided biopsy is a stereotactic-based procedure that, by using intravenous iodinated contrast media administration and dual-energy acquisition, provides localisation of enhancing lesions. All the biopsies were performed using a vacuum-assisted device. We collected procedural characteristics (patient position and type of approach), and histopathological results. Feasibility endpoints included success (visualisation of the enhancing lesion, post-procedural biopsy changes and clip placement), procedural time, number of scout acquisitions and complications. Results A total of 66 suspicious enhancing lesions (18.0% foci, 44.0% mass, 38.0% non-mass enhancement; median size 8.5 mm) in 64 patients (median age 59 years, mostly minimal [48.4%] or mild [32.8%] background parenchymal enhancement) were referred for CEM-guided biopsy in the study period. The success rate was 63/66 (95.4%). Amongst successful procedures, patients were most frequently seated (52/63, 82.5%) and the preferred approach was horizontal (48/63, 76.2%). Median total time per procedure was 15 min. Median number of acquisitions needed before targeting was 2 (range 1-4). Complications consisted of hematoma (17/63, 27%) and vasovagal reaction (2/63, 3.2%). At histology, the malignancy rate was 25/63 (39.7%). Conclusion In this first patient series, CEM-guided breast biopsy was feasible, with success and complication rates similar to those previously reported for magnetic resonance guidance.
2023
33
1
417
428
Contrast-enhanced mammography-guided biopsy: technical feasibility and first outcomes / Alcantara, R.; Posso, M.; Pitarch, M.; Arenas, N.; Ejarque, B.; Iotti, V.; Besutti, G.. - In: EUROPEAN RADIOLOGY. - ISSN 1432-1084. - 33:1(2023), pp. 417-428. [10.1007/s00330-022-09021-w]
Alcantara, R.; Posso, M.; Pitarch, M.; Arenas, N.; Ejarque, B.; Iotti, V.; Besutti, G.
File in questo prodotto:
File Dimensione Formato  
330_2022_Article_9021.pdf

Open access

Descrizione: Contrast-enhanced mammography-guided biopsy: technical feasibility and first outcomes
Tipologia: Versione pubblicata dall'editore
Dimensione 7.07 MB
Formato Adobe PDF
7.07 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1294668
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 16
social impact