The aim of this retrospective multicenter observational study is to test the feasibility and safety of a combined extracorporeal CO 2 removal (ECCO 2 R) plus renal replacement therapy (RRT) system to use an ultraprotective ventilator setting while maintaining (1) an effective support of renal function and (2) values of pH within the physiologic limits in a cohort of coronavirus infectious disease 2019 (COVID-19) patients. Among COVID-19 patients admitted to the intensive care unit of 9 participating hospitals, 27 patients with acute respiratory distress syndrome (ARDS) and acute kidney injury (AKI) requiring invasive mechanical ventilation undergoing ECCO 2 R-plus-RRT treatment were included in the analysis. The treatment allowed to reduce V T from 6.0 ± 0.6 mL/kg at baseline to 4.8 ± 0.8, 4.6 ± 1.0, and 4.3 ± 0.3 mL/kg, driving pressure (ΔP) from 19.8 ± 2.5 cm H 2 O to 14.8 ± 3.6, 14.38 ± 4.1 and 10.2 ± 1.6 cm H 2 O after 24 hours, 48 hours, and at discontinuation of ECCO 2 R-plus-RRT (T3), respectively ( p < 0.001). PaCO 2 and pH remained stable. Plasma creatinine decreased over the study period from 3.30 ± 1.27 to 1.90 ± 1.30 and 1.27 ± 0.90 mg/dL after 24 and 48 hours of treatment, respectively ( p < 0.01). No patient-related events associated with the extracorporeal system were reported. These data show that in patients with COVID-19-induced ARDS and AKI, ECCO 2 R-plus-RRT is effective in allowing ultraprotective ventilator settings while maintaining an effective support of renal function and values of pH within physiologic limits.
Extracorporeal CO 2 Removal During Renal Replacement Therapy to Allow Lung-Protective Ventilation in Patients With COVID-19-Associated Acute Respiratory Distress Syndrome / Alessandri, F.; Tonetti, T.; Pistidda, L.; Busani, S.; Borrazzo, C.; Fanelli, V.; Polzoni, M.; Piazza, O.; Lorini, L.; Cattaneo, S.; Ricci, D.; Zanoni, A.; Girardis, M.; Terragni, P.; Tempesta, M.; Di Luca, M.; Pugliese, F.; Ranieri, V. M.. - In: ASAIO JOURNAL. - ISSN 1058-2916. - 69:1(2023), pp. 36-42. [10.1097/MAT.0000000000001803]
Extracorporeal CO 2 Removal During Renal Replacement Therapy to Allow Lung-Protective Ventilation in Patients With COVID-19-Associated Acute Respiratory Distress Syndrome
Busani S.Membro del Collaboration Group
;Girardis M.;
2023
Abstract
The aim of this retrospective multicenter observational study is to test the feasibility and safety of a combined extracorporeal CO 2 removal (ECCO 2 R) plus renal replacement therapy (RRT) system to use an ultraprotective ventilator setting while maintaining (1) an effective support of renal function and (2) values of pH within the physiologic limits in a cohort of coronavirus infectious disease 2019 (COVID-19) patients. Among COVID-19 patients admitted to the intensive care unit of 9 participating hospitals, 27 patients with acute respiratory distress syndrome (ARDS) and acute kidney injury (AKI) requiring invasive mechanical ventilation undergoing ECCO 2 R-plus-RRT treatment were included in the analysis. The treatment allowed to reduce V T from 6.0 ± 0.6 mL/kg at baseline to 4.8 ± 0.8, 4.6 ± 1.0, and 4.3 ± 0.3 mL/kg, driving pressure (ΔP) from 19.8 ± 2.5 cm H 2 O to 14.8 ± 3.6, 14.38 ± 4.1 and 10.2 ± 1.6 cm H 2 O after 24 hours, 48 hours, and at discontinuation of ECCO 2 R-plus-RRT (T3), respectively ( p < 0.001). PaCO 2 and pH remained stable. Plasma creatinine decreased over the study period from 3.30 ± 1.27 to 1.90 ± 1.30 and 1.27 ± 0.90 mg/dL after 24 and 48 hours of treatment, respectively ( p < 0.01). No patient-related events associated with the extracorporeal system were reported. These data show that in patients with COVID-19-induced ARDS and AKI, ECCO 2 R-plus-RRT is effective in allowing ultraprotective ventilator settings while maintaining an effective support of renal function and values of pH within physiologic limits.File | Dimensione | Formato | |
---|---|---|---|
AlessandriASAIOJ.pdf
Accesso riservato
Tipologia:
VOR - Versione pubblicata dall'editore
Dimensione
684.99 kB
Formato
Adobe PDF
|
684.99 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris