In this work, flexible dispense-printed biosensors for AFM1 detection in milk were fabricated on polyethylene terephthalate (PET) substrate employing sodium hydroxide (NaOH) bath and oxygen plasma (OP) pre-treatment. Thanks to the use of dispense-printed silver and silver/silver chloride electrodes, our flexible biosensors are able to detect a minimum AFM1 concentration of 0.010 μg/L, which is to the best of our knowledge the the best lower level of detection ever reported for AFM1 sensors. Even if sensors with untreated and treated electrodes yield the same sensitivity, NaOH bath and OP pre-treatments result in a reduction of the electrode resistance by 46%, and 21.6%, respectively. These results prove that pre-treatment is a useful technique to modify the electrical and surface properties of the dispense-printed electrodes, by removing binder polymers and impurities of the employed ink paste. Bendability tests showed a maintaned fuctionality even after 1000 bending cycles down to 9 mm radius with variations below 11%.

Flexible Dispense-Printed Electrochemical Biosensor for Aflatoxin M1 Detection Employing NaOH and Oxygen Plasma Electrode Pre-treatment / Abera, B; Falco, A; Ibba, P; Cantarella, G; Petti, L; Lugli, P. - (2019). (Intervento presentato al convegno 2019 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) tenutosi a Glasgow nel 2.7.2019 - 10.7.2019) [10.1109/FLEPS.2019.8792320].

Flexible Dispense-Printed Electrochemical Biosensor for Aflatoxin M1 Detection Employing NaOH and Oxygen Plasma Electrode Pre-treatment

Cantarella G;
2019

Abstract

In this work, flexible dispense-printed biosensors for AFM1 detection in milk were fabricated on polyethylene terephthalate (PET) substrate employing sodium hydroxide (NaOH) bath and oxygen plasma (OP) pre-treatment. Thanks to the use of dispense-printed silver and silver/silver chloride electrodes, our flexible biosensors are able to detect a minimum AFM1 concentration of 0.010 μg/L, which is to the best of our knowledge the the best lower level of detection ever reported for AFM1 sensors. Even if sensors with untreated and treated electrodes yield the same sensitivity, NaOH bath and OP pre-treatments result in a reduction of the electrode resistance by 46%, and 21.6%, respectively. These results prove that pre-treatment is a useful technique to modify the electrical and surface properties of the dispense-printed electrodes, by removing binder polymers and impurities of the employed ink paste. Bendability tests showed a maintaned fuctionality even after 1000 bending cycles down to 9 mm radius with variations below 11%.
2019
2019 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)
Glasgow
2.7.2019 - 10.7.2019
Abera, B; Falco, A; Ibba, P; Cantarella, G; Petti, L; Lugli, P
Flexible Dispense-Printed Electrochemical Biosensor for Aflatoxin M1 Detection Employing NaOH and Oxygen Plasma Electrode Pre-treatment / Abera, B; Falco, A; Ibba, P; Cantarella, G; Petti, L; Lugli, P. - (2019). (Intervento presentato al convegno 2019 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) tenutosi a Glasgow nel 2.7.2019 - 10.7.2019) [10.1109/FLEPS.2019.8792320].
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1290885
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 0
social impact