Optical Microscopy has been applied to life science from its birth and reached widespread application due to its major advantages: limited perturbation of the biological tissue and the easy accessibility of the light sources. However, as the spatial and time resolution requirements and the time stability of the microscopes increase, researchers are struggling against some of its limitations: limited transparency and the refractivity of the living tissue to light and the field perturbations induced by the path in the tissue. We have developed a compact stand-Alone, completely scan-less, optical setup that allows to acquire non-linear excitation images and to measure the sample dynamics simultaneously on an ensemble of arbitrary chosen regions of interests. The image is obtained by shining a square array of spots on the sample obtained by a spatial light modulator and by shifting it (10 ms refresh time) on the sample. The final image is computed from the superposition of (100-1000) images. Filtering procedures can be applied to the raw images of the excitation array before building the image. We discuss results that show how this setup can be used for the correction of wave front aberrations induced by turbid samples (such as living tissues) and for the computation of space-Time cross-correlations in complex networks.

Scan-less nonlinear optical microscope for image reconstruction and space-Time correlation analysis / Ceffa, N.G., Radaelli, F., Pozzi, P., Collini, M., Sironi, L., D'Alfonso, L., Chirico, G.. - 10333:(2017), p. 103330E. (Optical Methods for Inspection, Characterization, and Imaging of Biomaterials III 2017 deu 2017) [10.1117/12.2271832].

Scan-less nonlinear optical microscope for image reconstruction and space-Time correlation analysis

Pozzi P.;
2017

Abstract

Optical Microscopy has been applied to life science from its birth and reached widespread application due to its major advantages: limited perturbation of the biological tissue and the easy accessibility of the light sources. However, as the spatial and time resolution requirements and the time stability of the microscopes increase, researchers are struggling against some of its limitations: limited transparency and the refractivity of the living tissue to light and the field perturbations induced by the path in the tissue. We have developed a compact stand-Alone, completely scan-less, optical setup that allows to acquire non-linear excitation images and to measure the sample dynamics simultaneously on an ensemble of arbitrary chosen regions of interests. The image is obtained by shining a square array of spots on the sample obtained by a spatial light modulator and by shifting it (10 ms refresh time) on the sample. The final image is computed from the superposition of (100-1000) images. Filtering procedures can be applied to the raw images of the excitation array before building the image. We discuss results that show how this setup can be used for the correction of wave front aberrations induced by turbid samples (such as living tissues) and for the computation of space-Time cross-correlations in complex networks.
2017
Inglese
Optical Methods for Inspection, Characterization, and Imaging of Biomaterials III 2017
deu
2017
Proceedings of SPIE - The International Society for Optical Engineering
Ferraro, Pietro
10333
103330E
9781510611115
SPIE
1000 20TH ST, PO BOX 10, BELLINGHAM, WA 98227-0010 USA
cross-correlation analysis of images; flow mapping.; optical imaging; Scan-less microscope
Ceffa, N. G.; Radaelli, F.; Pozzi, P.; Collini, M.; Sironi, L.; D'Alfonso, L.; Chirico, G.
Atti di CONVEGNO::Relazione in Atti di Convegno
273
7
Scan-less nonlinear optical microscope for image reconstruction and space-Time correlation analysis / Ceffa, N.G., Radaelli, F., Pozzi, P., Collini, M., Sironi, L., D'Alfonso, L., Chirico, G.. - 10333:(2017), p. 103330E. (Optical Methods for Inspection, Characterization, and Imaging of Biomaterials III 2017 deu 2017) [10.1117/12.2271832].
none
info:eu-repo/semantics/conferenceObject
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1289425
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact