Here, the authors report on the manufacturing and in vivo assessment of a bioresorbable nanostructured pH sensor. The sensor consists of a micrometer-thick porous silica membrane conformably coated layer-by-layer with a nanometer-thick multilayer stack of two polyelectrolytes labeled with a pH-insensitive fluorophore. The sensor fluorescence changes linearly with the pH value in the range 4 to 7.5 upon swelling/shrinking of the polymer multilayer and enables performing real-time measurements of the pH level with high stability, reproducibility, and accuracy, over 100 h of continuous operation. In vivo studies carried out implanting the sensor in the subcutis on the back of mice confirm real-time monitoring of the local pH level through skin. Full degradation of the pH sensor occurs in one week from implant in the animal model, and its biocompatibility after 2 months is confirmed by histological and fluorescence analyses. The proposed approach can be extended to the detection of other (bio)markers in vivo by engineering the functionality of one (at least) of the polyelectrolytes with suitable receptors, thus paving the way to implantable bioresorbable chemical sensors.

Bioresorbable Nanostructured Chemical Sensor for Monitoring of pH Level In Vivo / Corsi, Martina; Paghi, Alessandro; Mariani, Stefano; Golinelli, Giulia; Debrassi, Aline; Egri, Gabriella; Leo, Giuseppina; Vandini, Eleonora; Vilella, Antonietta; Dähne, Lars; Giuliani, Daniela; Barillaro, Giuseppe. - In: ADVANCED SCIENCE. - ISSN 2198-3844. - 9:22(2022), pp. N/A-N/A. [10.1002/advs.202202062]

Bioresorbable Nanostructured Chemical Sensor for Monitoring of pH Level In Vivo

Golinelli, Giulia;Leo, Giuseppina;Vilella, Antonietta;Giuliani, Daniela;
2022

Abstract

Here, the authors report on the manufacturing and in vivo assessment of a bioresorbable nanostructured pH sensor. The sensor consists of a micrometer-thick porous silica membrane conformably coated layer-by-layer with a nanometer-thick multilayer stack of two polyelectrolytes labeled with a pH-insensitive fluorophore. The sensor fluorescence changes linearly with the pH value in the range 4 to 7.5 upon swelling/shrinking of the polymer multilayer and enables performing real-time measurements of the pH level with high stability, reproducibility, and accuracy, over 100 h of continuous operation. In vivo studies carried out implanting the sensor in the subcutis on the back of mice confirm real-time monitoring of the local pH level through skin. Full degradation of the pH sensor occurs in one week from implant in the animal model, and its biocompatibility after 2 months is confirmed by histological and fluorescence analyses. The proposed approach can be extended to the detection of other (bio)markers in vivo by engineering the functionality of one (at least) of the polyelectrolytes with suitable receptors, thus paving the way to implantable bioresorbable chemical sensors.
2022
9
22
N/A
N/A
Bioresorbable Nanostructured Chemical Sensor for Monitoring of pH Level In Vivo / Corsi, Martina; Paghi, Alessandro; Mariani, Stefano; Golinelli, Giulia; Debrassi, Aline; Egri, Gabriella; Leo, Giuseppina; Vandini, Eleonora; Vilella, Antonietta; Dähne, Lars; Giuliani, Daniela; Barillaro, Giuseppe. - In: ADVANCED SCIENCE. - ISSN 2198-3844. - 9:22(2022), pp. N/A-N/A. [10.1002/advs.202202062]
Corsi, Martina; Paghi, Alessandro; Mariani, Stefano; Golinelli, Giulia; Debrassi, Aline; Egri, Gabriella; Leo, Giuseppina; Vandini, Eleonora; Vilella, Antonietta; Dähne, Lars; Giuliani, Daniela; Barillaro, Giuseppe
File in questo prodotto:
File Dimensione Formato  
Advanced Science - 2022 - Corsi - Bioresorbable Nanostructured Chemical Sensor for Monitoring of pH Level In Vivo.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 2.65 MB
Formato Adobe PDF
2.65 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1288428
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 18
social impact