Concrete core subjected to confinement effect from steel tube is the main advantage of concretefilled steel tubular (CFST) column under compression. However, the debonding of concrete to steel tube which is a common phenomenon in real structures will have an unfavorable effect on the confinement. In this paper, the influence of debonding on CFST stub columns subjected to eccentric loading was investigated experimentally. The debonding gap was formed by inserting galvanized sheet in the steel tube before the concrete fill and by pulling them out after 5~6 hours. From the test, it was verified that the method to form the debonding gap of specimen is valid. The parameters in the test included the debonding arc-length ratio and steel ratio. All the specimens failed in flexural mode, which indicated that the debonding has no influence on the failure modes. The ultimate load capacity and the ductility of the specimens were significantly decreased with the increased debonding arc-length ratio, while this unfavorable influence would decrease with the steel ratio increase.

Experimental research on debonding in concrete-filled steel tubes columns subjected to eccentric loading / Xue, J.; Chen, B.; Briseghella, B.. - (2010), pp. 132-133. (Intervento presentato al convegno 34th International Symposium on Bridge and Structural Engineering: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas tenutosi a ita nel 2010).

Experimental research on debonding in concrete-filled steel tubes columns subjected to eccentric loading

Briseghella B.
2010

Abstract

Concrete core subjected to confinement effect from steel tube is the main advantage of concretefilled steel tubular (CFST) column under compression. However, the debonding of concrete to steel tube which is a common phenomenon in real structures will have an unfavorable effect on the confinement. In this paper, the influence of debonding on CFST stub columns subjected to eccentric loading was investigated experimentally. The debonding gap was formed by inserting galvanized sheet in the steel tube before the concrete fill and by pulling them out after 5~6 hours. From the test, it was verified that the method to form the debonding gap of specimen is valid. The parameters in the test included the debonding arc-length ratio and steel ratio. All the specimens failed in flexural mode, which indicated that the debonding has no influence on the failure modes. The ultimate load capacity and the ductility of the specimens were significantly decreased with the increased debonding arc-length ratio, while this unfavorable influence would decrease with the steel ratio increase.
2010
34th International Symposium on Bridge and Structural Engineering: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas
ita
2010
132
133
Xue, J.; Chen, B.; Briseghella, B.
Experimental research on debonding in concrete-filled steel tubes columns subjected to eccentric loading / Xue, J.; Chen, B.; Briseghella, B.. - (2010), pp. 132-133. (Intervento presentato al convegno 34th International Symposium on Bridge and Structural Engineering: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas tenutosi a ita nel 2010).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1287439
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact