To enhance the durability of side-by-side box girder bridges, a common source of maintenance issues can be eliminated using the jointless bridge concept. Accurate estimation of the average effective bridge temperature range is a key issue. A deck-extension bridge containing side-by-side box girders was chosen as case study. The temperature distribution on the bridge cross section and the longitudinal thermal movement of the superstructure were monitored. Finite-element models of the bridge superstructure were developed, which indicated close agreement with measured temperature responses. The average effective temperature of girder cross sections could accurately predict the longitudinal thermal movement of the superstructure. The highest and lowest average effective bridge temperatures for side-by-side box girders were estimated for 12 cities in 4 climatic regions in China under historically extreme temperature conditions. For most cities, the difference between the highest and lowest average effective bridge temperatures exceeded the design temperature range. The Chinese-code design procedures may overestimate the allowable length of deck-extension bridges, because the code underpredicts the change in the average effective bridge temperature.

Temperature Monitoring and Response of Deck-Extension Side-by-Side Box Girder Bridges / Briseghella, Bruno. - In: JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES. - ISSN 0887-3828. - 34:2(2020), pp. N/A-N/A. [10.1061/(ASCE)CF.1943-5509.0001399]

Temperature Monitoring and Response of Deck-Extension Side-by-Side Box Girder Bridges

BRISEGHELLA
2020

Abstract

To enhance the durability of side-by-side box girder bridges, a common source of maintenance issues can be eliminated using the jointless bridge concept. Accurate estimation of the average effective bridge temperature range is a key issue. A deck-extension bridge containing side-by-side box girders was chosen as case study. The temperature distribution on the bridge cross section and the longitudinal thermal movement of the superstructure were monitored. Finite-element models of the bridge superstructure were developed, which indicated close agreement with measured temperature responses. The average effective temperature of girder cross sections could accurately predict the longitudinal thermal movement of the superstructure. The highest and lowest average effective bridge temperatures for side-by-side box girders were estimated for 12 cities in 4 climatic regions in China under historically extreme temperature conditions. For most cities, the difference between the highest and lowest average effective bridge temperatures exceeded the design temperature range. The Chinese-code design procedures may overestimate the allowable length of deck-extension bridges, because the code underpredicts the change in the average effective bridge temperature.
2020
34
2
N/A
N/A
Temperature Monitoring and Response of Deck-Extension Side-by-Side Box Girder Bridges / Briseghella, Bruno. - In: JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES. - ISSN 0887-3828. - 34:2(2020), pp. N/A-N/A. [10.1061/(ASCE)CF.1943-5509.0001399]
Briseghella, Bruno
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1287332
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 27
social impact