CLT panels are becoming a widespread structural solution in the realization of new timber structures and, besides, they can be adopted for seismic retrofitting of existing structures such as Reinforced Concrete (RC) frame buildings. Moreover, the use of CLT panels can improve the energetic efficiency as well as other architectural parameters of an existing structures. In this work, an existing 100m tall RC frame-wall building located in Huizhou, China, was chosen as case study. The aims of the study were: 1) analyzing the structural performances of the building, without retrofitting, by means of a nonlinear pushover analysis in order to define structural weaknesses with respect to earthquake actions; 2) propose an architectural solution, where timber panels were positioned in a rational way with respect to architectural functions; therefore re-organizing the internal space and re-designing the existing facades. 3) verify the new structural performances after retrofitting with CLT panels.Additionally, studies on the energy efficiency, quality of the air, natural lighting were performed.

Chinese high rise reinforced concrete building retrofitted with CLT Panels / Contiguglia, C. P.; Bergami, A. V.; Fiorentino, G.; Lavorato, D.; Nuti, C.; Lai, Z.; Briseghella, B.. - (2020), pp. 902-909. (Intervento presentato al convegno 7th International Symposium on Life-Cycle Civil Engineering, IALCCE 2020 tenutosi a chn nel 2020) [10.1201/9780429343292-119].

Chinese high rise reinforced concrete building retrofitted with CLT Panels

B. Briseghella
2020

Abstract

CLT panels are becoming a widespread structural solution in the realization of new timber structures and, besides, they can be adopted for seismic retrofitting of existing structures such as Reinforced Concrete (RC) frame buildings. Moreover, the use of CLT panels can improve the energetic efficiency as well as other architectural parameters of an existing structures. In this work, an existing 100m tall RC frame-wall building located in Huizhou, China, was chosen as case study. The aims of the study were: 1) analyzing the structural performances of the building, without retrofitting, by means of a nonlinear pushover analysis in order to define structural weaknesses with respect to earthquake actions; 2) propose an architectural solution, where timber panels were positioned in a rational way with respect to architectural functions; therefore re-organizing the internal space and re-designing the existing facades. 3) verify the new structural performances after retrofitting with CLT panels.Additionally, studies on the energy efficiency, quality of the air, natural lighting were performed.
2020
7th International Symposium on Life-Cycle Civil Engineering, IALCCE 2020
chn
2020
902
909
Contiguglia, C. P.; Bergami, A. V.; Fiorentino, G.; Lavorato, D.; Nuti, C.; Lai, Z.; Briseghella, B.
Chinese high rise reinforced concrete building retrofitted with CLT Panels / Contiguglia, C. P.; Bergami, A. V.; Fiorentino, G.; Lavorato, D.; Nuti, C.; Lai, Z.; Briseghella, B.. - (2020), pp. 902-909. (Intervento presentato al convegno 7th International Symposium on Life-Cycle Civil Engineering, IALCCE 2020 tenutosi a chn nel 2020) [10.1201/9780429343292-119].
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1287221
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact