OBJECTIVES: To develop a quality assessment tool which will be used in systematic reviews to assess the quality of primary studies of diagnostic accuracy. DATA SOURCES: Electronic databases including MEDLINE, EMBASE, BIOSIS and the methodological databases of both CRD and the Cochrane Collaboration. REVIEW METHODS: Three systematic reviews were conducted to provide an evidence base for the development of the quality assessment tool. A Delphi procedure was used to develop the quality assessment tool and the information provided by the reviews was incorporated into this. A panel of nine experts in the area of diagnostic accuracy studies took part in the Delphi procedure to agree on the items to be included in the tool. Panel members were also asked to provide feedback on various other items and whether they would like to see the development of additional topic and design specific items. The Delphi procedure produced the quality assessment tool, named the QUADAS tool, which consisted of 14 items. A background document was produced describing each item included in the tool and how each of the items should be scored. RESULTS: The reviews produced 28 possible items for inclusion in the quality assessment tool. It was found that the sources of bias supported by the most empirical evidence were variation by clinical and demographic subgroups, disease prevalence/severity, partial verification bias, clinical review bias and observer/instrument variation. There was also some evidence of bias for the effects of distorted selection of participants, absent or inappropriate reference standard, differential verification bias and review bias. The evidence for the effects of other sources of bias was insufficient to draw conclusions. The third review found that only one item, the avoidance of review bias, was included in more than 75% of tools. Spectrum composition, population recruitment, absent or inappropriate reference standard and verification bias were each included in 50-75% of tools. Other items were included in less than 50% of tools. The second review found that the quality assessment tool should have the potential to be discussed narratively, reported in a tabular summary, used as recommendations for future research, used to conduct sensitivity or regression analyses and used as criteria for inclusion in the review or a primary analysis. This suggested that some distinction is needed between high- and low-quality studies. Component analysis was considered the best approach to incorporate quality into systematic reviews of diagnostic studies and this was taken into consideration when developing the tool. CONCLUSIONS: This project produced an evidence-based quality assessment tool to be used in systematic reviews of diagnostic accuracy studies. Through the various stages of the project the current lack of such a tool and the need for a systematically developed validated tool were demonstrated. Further work to validate the tool continues beyond the scope of this project. The further development of the tool by the addition of design- and topic-specific criteria is proposed.

Development and validation of methods for assessing the quality of diagnostic accuracy studies / Whiting, P; Rutjes, A; Dinnes, J; Reitsma, J; Bossuyt, Pm; Kleijnen, J. - (2004), pp. iii-234. [10.3310/hta8250]

Development and validation of methods for assessing the quality of diagnostic accuracy studies

Rutjes A;
2004

Abstract

OBJECTIVES: To develop a quality assessment tool which will be used in systematic reviews to assess the quality of primary studies of diagnostic accuracy. DATA SOURCES: Electronic databases including MEDLINE, EMBASE, BIOSIS and the methodological databases of both CRD and the Cochrane Collaboration. REVIEW METHODS: Three systematic reviews were conducted to provide an evidence base for the development of the quality assessment tool. A Delphi procedure was used to develop the quality assessment tool and the information provided by the reviews was incorporated into this. A panel of nine experts in the area of diagnostic accuracy studies took part in the Delphi procedure to agree on the items to be included in the tool. Panel members were also asked to provide feedback on various other items and whether they would like to see the development of additional topic and design specific items. The Delphi procedure produced the quality assessment tool, named the QUADAS tool, which consisted of 14 items. A background document was produced describing each item included in the tool and how each of the items should be scored. RESULTS: The reviews produced 28 possible items for inclusion in the quality assessment tool. It was found that the sources of bias supported by the most empirical evidence were variation by clinical and demographic subgroups, disease prevalence/severity, partial verification bias, clinical review bias and observer/instrument variation. There was also some evidence of bias for the effects of distorted selection of participants, absent or inappropriate reference standard, differential verification bias and review bias. The evidence for the effects of other sources of bias was insufficient to draw conclusions. The third review found that only one item, the avoidance of review bias, was included in more than 75% of tools. Spectrum composition, population recruitment, absent or inappropriate reference standard and verification bias were each included in 50-75% of tools. Other items were included in less than 50% of tools. The second review found that the quality assessment tool should have the potential to be discussed narratively, reported in a tabular summary, used as recommendations for future research, used to conduct sensitivity or regression analyses and used as criteria for inclusion in the review or a primary analysis. This suggested that some distinction is needed between high- and low-quality studies. Component analysis was considered the best approach to incorporate quality into systematic reviews of diagnostic studies and this was taken into consideration when developing the tool. CONCLUSIONS: This project produced an evidence-based quality assessment tool to be used in systematic reviews of diagnostic accuracy studies. Through the various stages of the project the current lack of such a tool and the need for a systematically developed validated tool were demonstrated. Further work to validate the tool continues beyond the scope of this project. The further development of the tool by the addition of design- and topic-specific criteria is proposed.
2004
Development and validation of methods for assessing the quality of diagnostic accuracy studies / Whiting, P; Rutjes, A; Dinnes, J; Reitsma, J; Bossuyt, Pm; Kleijnen, J. - (2004), pp. iii-234. [10.3310/hta8250]
Whiting, P; Rutjes, A; Dinnes, J; Reitsma, J; Bossuyt, Pm; Kleijnen, J
File in questo prodotto:
File Dimensione Formato  
2004_Whiting_Rutjes_HTA.pdf

Accesso riservato

Dimensione 839.69 kB
Formato Adobe PDF
839.69 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1286711
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 289
  • ???jsp.display-item.citation.isi??? 414
social impact