OBJECTIVES: The aim was to analyze the data about the effects on marginal bone resorption and implant failure rates between implants inserted with high or low insertion torque values. MATERIALS AND METHODS: A systematic literature search until July 2015 was conducted. Data were summarized qualitatively in descriptive tables and quantitatively by performing random effects meta-analyses of effect sizes (ESs) for bone resorption and bone-to-implant contact (BIC) and relative risks (RRs) for implant failures. Risk of bias assessments were performed using the Cochrane tool for human studies and the SYRCLE's tool for animal studies. RESULTS: Four studies in humans and 6 quasirandomized animal studies were included. A total of 591 implants were evaluated qualitatively: 348 installed with high insertion torque (>25 Ncm, up to 176 Ncm) and 243 implants inserted with low torque values (<30-35 Ncm). No significant differences were detected for bone resorption (ES, 0.13; 95% confidence interval [CI], -0.12 to 0.38 in human studies; ES predictive interval from 35.03 to 34.50 in animal studies), implant failure (RR, 0.39; 95% CI, 0.01-20.77 in human studies; RR, 2.05; 95% CI, 0.19-21.71 in animal studies), or BIC (ES predictive interval from -3.84 to 5.13 in animal studies). CONCLUSION: The current review indicated that there is no significant difference in marginal bone resorption and implant failure rate between implants inserted with high or low insertion torque values.

The Effects of High Insertion Torque Versus Low Insertion Torque on Marginal Bone Resorption and Implant Failure Rates: A Systematic Review With Meta-Analyses / Berardini, M; Trisi, P; Sinjari, B; Rutjes, A; Caputi, S. - In: IMPLANT DENTISTRY. - ISSN 1056-6163. - 25:4(2016), pp. 532-540. [10.1097/ID.0000000000000422]

The Effects of High Insertion Torque Versus Low Insertion Torque on Marginal Bone Resorption and Implant Failure Rates: A Systematic Review With Meta-Analyses

Rutjes A;
2016

Abstract

OBJECTIVES: The aim was to analyze the data about the effects on marginal bone resorption and implant failure rates between implants inserted with high or low insertion torque values. MATERIALS AND METHODS: A systematic literature search until July 2015 was conducted. Data were summarized qualitatively in descriptive tables and quantitatively by performing random effects meta-analyses of effect sizes (ESs) for bone resorption and bone-to-implant contact (BIC) and relative risks (RRs) for implant failures. Risk of bias assessments were performed using the Cochrane tool for human studies and the SYRCLE's tool for animal studies. RESULTS: Four studies in humans and 6 quasirandomized animal studies were included. A total of 591 implants were evaluated qualitatively: 348 installed with high insertion torque (>25 Ncm, up to 176 Ncm) and 243 implants inserted with low torque values (<30-35 Ncm). No significant differences were detected for bone resorption (ES, 0.13; 95% confidence interval [CI], -0.12 to 0.38 in human studies; ES predictive interval from 35.03 to 34.50 in animal studies), implant failure (RR, 0.39; 95% CI, 0.01-20.77 in human studies; RR, 2.05; 95% CI, 0.19-21.71 in animal studies), or BIC (ES predictive interval from -3.84 to 5.13 in animal studies). CONCLUSION: The current review indicated that there is no significant difference in marginal bone resorption and implant failure rate between implants inserted with high or low insertion torque values.
2016
25
4
532
540
The Effects of High Insertion Torque Versus Low Insertion Torque on Marginal Bone Resorption and Implant Failure Rates: A Systematic Review With Meta-Analyses / Berardini, M; Trisi, P; Sinjari, B; Rutjes, A; Caputi, S. - In: IMPLANT DENTISTRY. - ISSN 1056-6163. - 25:4(2016), pp. 532-540. [10.1097/ID.0000000000000422]
Berardini, M; Trisi, P; Sinjari, B; Rutjes, A; Caputi, S
File in questo prodotto:
File Dimensione Formato  
2016_berardini_rutjes.pdf

Accesso riservato

Dimensione 787.14 kB
Formato Adobe PDF
787.14 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1286602
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 41
social impact