Objective. This project compared a new method to estimate the carotid-femoral pulse wave velocity (cf-PWV) to the gold-standard cf-PWV technique.Approach. The cf-PWV was estimated from the pulse transit time (FPS-PTT) calculated by processing the finger photoplethysmographic signal of Finapres (FPS) and subject's height only (brief mode) as well as along with other variables (age, heart rate, arterial pressure, weight; complete mode). Doppler ultrasound cf-PWVs and FPS-PTTs were measured in 90 participants equally divided into 3 groups (18-30; 31-59; 60-79 years). Predictions were performed using multiple linear regressions (MLR) and with the best regression model identified by using MATLAB Regression Learner App. A validation set approach (60 training datasets, 30 testing datasets; VSA) and leave-one-out cross-validation (LOOCV) were used.Main results. With MLR, the discrepancies were: 0.01 ± 1.21 m s-1(VSA) and 0.001 ± 1.11 m s-1(LOOCV) in brief mode; -0.02 ± 0.83 m s-1(VSA) and 0.001 ± 0.84 m s-1(LOOCV) in complete mode. Using a linear support vector machine model (SVM) in brief mode, the discrepancies were: 0.01 ± 1.19 m s-1(VSA) and -0.01 ± 1.06 m s-1(LOOCV). Using an Exponential Gaussian process regression model (GPR) in complete mode, the discrepancies were: -0.03 ± 0.79 m s-1(VSA) and 0.01 ± 0.75 m s-1(LOOCV).Significance. The cf-PWV can be estimated by processing the FPS-PTT and subjects' height only, but the inclusion of other variables improves the prediction performance. Predictions through MLR qualify as acceptable in both brief and complete modes. Predictions via linear SVM in brief mode improve but still qualify as acceptable. Interestingly, predictions through Exponential GPR in complete mode improve and qualify as excellent.

Estimation of carotid-femoral pulse wave velocity from finger photoplethysmography signal / Gentilin, Alessandro; Tarperi, Cantor; Cevese, Antonio; Mattioli, Anna Vittoria; Schena, Federico. - In: PHYSIOLOGICAL MEASUREMENT. - ISSN 0967-3334. - 43:7(2022), pp. 075011-075011. [10.1088/1361-6579/ac7a8e]

Estimation of carotid-femoral pulse wave velocity from finger photoplethysmography signal

Mattioli, Anna Vittoria
Membro del Collaboration Group
;
2022

Abstract

Objective. This project compared a new method to estimate the carotid-femoral pulse wave velocity (cf-PWV) to the gold-standard cf-PWV technique.Approach. The cf-PWV was estimated from the pulse transit time (FPS-PTT) calculated by processing the finger photoplethysmographic signal of Finapres (FPS) and subject's height only (brief mode) as well as along with other variables (age, heart rate, arterial pressure, weight; complete mode). Doppler ultrasound cf-PWVs and FPS-PTTs were measured in 90 participants equally divided into 3 groups (18-30; 31-59; 60-79 years). Predictions were performed using multiple linear regressions (MLR) and with the best regression model identified by using MATLAB Regression Learner App. A validation set approach (60 training datasets, 30 testing datasets; VSA) and leave-one-out cross-validation (LOOCV) were used.Main results. With MLR, the discrepancies were: 0.01 ± 1.21 m s-1(VSA) and 0.001 ± 1.11 m s-1(LOOCV) in brief mode; -0.02 ± 0.83 m s-1(VSA) and 0.001 ± 0.84 m s-1(LOOCV) in complete mode. Using a linear support vector machine model (SVM) in brief mode, the discrepancies were: 0.01 ± 1.19 m s-1(VSA) and -0.01 ± 1.06 m s-1(LOOCV). Using an Exponential Gaussian process regression model (GPR) in complete mode, the discrepancies were: -0.03 ± 0.79 m s-1(VSA) and 0.01 ± 0.75 m s-1(LOOCV).Significance. The cf-PWV can be estimated by processing the FPS-PTT and subjects' height only, but the inclusion of other variables improves the prediction performance. Predictions through MLR qualify as acceptable in both brief and complete modes. Predictions via linear SVM in brief mode improve but still qualify as acceptable. Interestingly, predictions through Exponential GPR in complete mode improve and qualify as excellent.
2022
43
7
075011
075011
Estimation of carotid-femoral pulse wave velocity from finger photoplethysmography signal / Gentilin, Alessandro; Tarperi, Cantor; Cevese, Antonio; Mattioli, Anna Vittoria; Schena, Federico. - In: PHYSIOLOGICAL MEASUREMENT. - ISSN 0967-3334. - 43:7(2022), pp. 075011-075011. [10.1088/1361-6579/ac7a8e]
Gentilin, Alessandro; Tarperi, Cantor; Cevese, Antonio; Mattioli, Anna Vittoria; Schena, Federico
File in questo prodotto:
File Dimensione Formato  
Gentilin_2022_Physiol._Meas._43_075011.pdf

Open Access dal 01/09/2023

Tipologia: Versione pubblicata dall'editore
Dimensione 1.96 MB
Formato Adobe PDF
1.96 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1284038
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 6
social impact