This study aimed to evaluate contrast-enhanced mammography (CEM) accuracy and reproducibility in the detection and measurement of residual tumor after neoadjuvant chemotherapy (NAC) in breast cancer (BC) patients with calcifications, using surgical specimen pathology as the reference. Pre-and post-NAC CEM images of 36 consecutive BC patients receiving NAC in 2012–2020, with calcifications in the tumor bed at diagnosis, were retrospectively reviewed by two radiologists; described were absence/presence and size of residual disease based on contrast enhancement (CE) only and CE plus calcifications. Twenty-eight patients (77.8%) had invasive and 5 (13.9%) in situ-only residual disease at surgical specimen pathology. Considering CE plus calcifications instead of CE only, CEM sensitivity for invasive residual tumor increased from 85.7% (95% CI = 67.3–96%) to 96.4% (95% CI = 81.7–99.9% ) and specificity decreased from 5/8 (62.5%; 95% CI = 24.5–91.5%) to 1/8 (14.3%; 95% CI = 0.4–57.9%). For in situ-only residual disease, false negatives decreased from 3 to 0 and false positives increased from 1 to 2. CEM pathology concordance in residual disease measurement increased (R squared from 0.38 to 0.45); inter-reader concordance decreased (R squared from 0.79 to 0.66). Considering CE plus calcifications to evaluate NAC response in BC patients increases sensitivity in detection and accuracy in measurement of residual disease but increases false positives.
Accuracy and reproducibility of contrast-enhanced mammography in the assessment of response to neoadjuvant chemotherapy in breast cancer patients with calcifications in the tumor bed / Iotti, V.; Ragazzi, M.; Besutti, G.; Marchesi, V.; Ravaioli, S.; Falco, G.; Coiro, S.; Bisagni, A.; Gasparini, E.; Rossi, P. G.; Vacondio, R.; Pattacini, P.. - In: DIAGNOSTICS. - ISSN 2075-4418. - 11:3(2021), pp. 435-N/A. [10.3390/diagnostics11030435]
Accuracy and reproducibility of contrast-enhanced mammography in the assessment of response to neoadjuvant chemotherapy in breast cancer patients with calcifications in the tumor bed
Ragazzi M.;Besutti G.;Ravaioli S.;
2021
Abstract
This study aimed to evaluate contrast-enhanced mammography (CEM) accuracy and reproducibility in the detection and measurement of residual tumor after neoadjuvant chemotherapy (NAC) in breast cancer (BC) patients with calcifications, using surgical specimen pathology as the reference. Pre-and post-NAC CEM images of 36 consecutive BC patients receiving NAC in 2012–2020, with calcifications in the tumor bed at diagnosis, were retrospectively reviewed by two radiologists; described were absence/presence and size of residual disease based on contrast enhancement (CE) only and CE plus calcifications. Twenty-eight patients (77.8%) had invasive and 5 (13.9%) in situ-only residual disease at surgical specimen pathology. Considering CE plus calcifications instead of CE only, CEM sensitivity for invasive residual tumor increased from 85.7% (95% CI = 67.3–96%) to 96.4% (95% CI = 81.7–99.9% ) and specificity decreased from 5/8 (62.5%; 95% CI = 24.5–91.5%) to 1/8 (14.3%; 95% CI = 0.4–57.9%). For in situ-only residual disease, false negatives decreased from 3 to 0 and false positives increased from 1 to 2. CEM pathology concordance in residual disease measurement increased (R squared from 0.38 to 0.45); inter-reader concordance decreased (R squared from 0.79 to 0.66). Considering CE plus calcifications to evaluate NAC response in BC patients increases sensitivity in detection and accuracy in measurement of residual disease but increases false positives.File | Dimensione | Formato | |
---|---|---|---|
diagnostics-11-00435-v2.pdf
Open access
Tipologia:
Versione pubblicata dall'editore
Dimensione
6.02 MB
Formato
Adobe PDF
|
6.02 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris