Purpose: Compare the accuracy of intraoral digital impression in full-arch implant-supported fixed dental prosthesis acquired with eight different intraoral scanner (Ios). Methods: A polymethyl methacrylate acrylic model of an edentulous mandible with six scan-abutment was used as a master model and its dimensions measured with a coordinate measuring machine. Eight different Ios were used to generate digital impression: True Definition, Trios, Cerec Omnicam, 3D progress, CS3500, CS3600, Planmeca Emelard and Dental Wings. Fifteen digital impressions were made. A software called “Scan-abut” was developed to analyse and compare the digital impression with the master model, obtaining the scanning accuracy. The three-dimensional (3D) position and distance analysis were performed. Results: Mean value of the 3D position analysis showed that the True Definition (31 μm ± 8 μm) and Trios (32 μm ± 5 μm) have the best performance of the group. The Cerec Omnicam (71 μm ± 55 μm), CS3600 (61 μm ± 14 μm) have an average performance. The CS3500 (107 μm ± 28 μm) and Planmeca Emelard (101 μm ± 38 μm) present a middle-low performance, while the 3D progress (344 μm ± 121 μm) and Dental Wings (148 μm ± 64 μm) show the low performance. The 3D distance analysis showed a good linear relationship between the errors and scan-abutment distance only with the True Definition and CS3600. Conclusions: Not all scanners are suitable for digital impression in full-arch implant-supported fixed dental prosthesis and the weight of the output files is independent from the accuracy of the Ios.

Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners / Di Fiore, A.; Meneghello, R.; Graiff, L.; Savio, G.; Vigolo, P.; Monaco, C.; Stellini, E.. - In: JOURNAL OF PROSTHODONTIC RESEARCH. - ISSN 1883-1958. - 63:4(2019), pp. 396-403. [10.1016/j.jpor.2019.04.002]

Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners

Monaco C.;
2019

Abstract

Purpose: Compare the accuracy of intraoral digital impression in full-arch implant-supported fixed dental prosthesis acquired with eight different intraoral scanner (Ios). Methods: A polymethyl methacrylate acrylic model of an edentulous mandible with six scan-abutment was used as a master model and its dimensions measured with a coordinate measuring machine. Eight different Ios were used to generate digital impression: True Definition, Trios, Cerec Omnicam, 3D progress, CS3500, CS3600, Planmeca Emelard and Dental Wings. Fifteen digital impressions were made. A software called “Scan-abut” was developed to analyse and compare the digital impression with the master model, obtaining the scanning accuracy. The three-dimensional (3D) position and distance analysis were performed. Results: Mean value of the 3D position analysis showed that the True Definition (31 μm ± 8 μm) and Trios (32 μm ± 5 μm) have the best performance of the group. The Cerec Omnicam (71 μm ± 55 μm), CS3600 (61 μm ± 14 μm) have an average performance. The CS3500 (107 μm ± 28 μm) and Planmeca Emelard (101 μm ± 38 μm) present a middle-low performance, while the 3D progress (344 μm ± 121 μm) and Dental Wings (148 μm ± 64 μm) show the low performance. The 3D distance analysis showed a good linear relationship between the errors and scan-abutment distance only with the True Definition and CS3600. Conclusions: Not all scanners are suitable for digital impression in full-arch implant-supported fixed dental prosthesis and the weight of the output files is independent from the accuracy of the Ios.
2019
63
4
396
403
Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners / Di Fiore, A.; Meneghello, R.; Graiff, L.; Savio, G.; Vigolo, P.; Monaco, C.; Stellini, E.. - In: JOURNAL OF PROSTHODONTIC RESEARCH. - ISSN 1883-1958. - 63:4(2019), pp. 396-403. [10.1016/j.jpor.2019.04.002]
Di Fiore, A.; Meneghello, R.; Graiff, L.; Savio, G.; Vigolo, P.; Monaco, C.; Stellini, E.
File in questo prodotto:
File Dimensione Formato  
j.jpor.2019.04.002.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 1.6 MB
Formato Adobe PDF
1.6 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1281235
Citazioni
  • ???jsp.display-item.citation.pmc??? 33
  • Scopus 92
  • ???jsp.display-item.citation.isi??? 79
social impact