Purpose: To evaluate the influence of the crown-to-implant ratio (CI) on marginal bone loss (MBL) around short dental implants placed in the posterior mandible. Materials and Methods: All patients treated with short implants (7-mm length) in the posterior mandible between 1994 and 2003 at the Dental Clinic of the Department of Neuroscience of the University of Padua (Italy) were retrospectively included in the analysis. MBL and clinical CI (cCI) were measured on the radiographs. Implant characteristics including implant diameter, prosthetic type, retention mode, antagonist type, veneering material, and implant surfaces were retrieved from local medical records. A generalized linear mixed model was estimated to identify the predictors of MBL. Results: A total of 108 dental implants placed in 51 patients were included in the analysis. Mean follow-up was 16 years (range: 11 to 20 years). Mean cCI was 2.21 (SD = 0.31) with a mean crown height of 10.86 mm (SD = 0.99). Mean MBL was 1.42 mm (SD = 0.38). At multivariable analysis, cCI ≥ 2 was associated with higher MBL (regression coefficient: 0.27; 95% CI: 0.15 to 0.40), while implant characteristics, follow-up, and site were not associated with MBL. The effect of a cCI ≥ 2 was estimated in an increase of 0.28 mm in MBL (95% CI: 0.14 to 0.43 mm). Conclusion: Higher cCI was associated with greater MBL of implant-supported fixed dental prostheses in short dental implants placed in the posterior mandible, while implant characteristics, follow-up, and site were not associated with MBL. However, the increase of 0.28 mm of MBL in patients with a cCI ≥ 2 may not be clinically relevant.

Influence of crown-to-implant ratio on long-term marginal bone loss around short implants / Di Fiore, A.; Vigolo, P.; Sivolella, S.; Cavallin, F.; Katsoulis, J.; Monaco, C.; Stellini, E.. - In: INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS. - ISSN 0882-2786. - 34:4(2019), pp. 992-998. [10.11607/jomi.7161]

Influence of crown-to-implant ratio on long-term marginal bone loss around short implants

Monaco C.;
2019

Abstract

Purpose: To evaluate the influence of the crown-to-implant ratio (CI) on marginal bone loss (MBL) around short dental implants placed in the posterior mandible. Materials and Methods: All patients treated with short implants (7-mm length) in the posterior mandible between 1994 and 2003 at the Dental Clinic of the Department of Neuroscience of the University of Padua (Italy) were retrospectively included in the analysis. MBL and clinical CI (cCI) were measured on the radiographs. Implant characteristics including implant diameter, prosthetic type, retention mode, antagonist type, veneering material, and implant surfaces were retrieved from local medical records. A generalized linear mixed model was estimated to identify the predictors of MBL. Results: A total of 108 dental implants placed in 51 patients were included in the analysis. Mean follow-up was 16 years (range: 11 to 20 years). Mean cCI was 2.21 (SD = 0.31) with a mean crown height of 10.86 mm (SD = 0.99). Mean MBL was 1.42 mm (SD = 0.38). At multivariable analysis, cCI ≥ 2 was associated with higher MBL (regression coefficient: 0.27; 95% CI: 0.15 to 0.40), while implant characteristics, follow-up, and site were not associated with MBL. The effect of a cCI ≥ 2 was estimated in an increase of 0.28 mm in MBL (95% CI: 0.14 to 0.43 mm). Conclusion: Higher cCI was associated with greater MBL of implant-supported fixed dental prostheses in short dental implants placed in the posterior mandible, while implant characteristics, follow-up, and site were not associated with MBL. However, the increase of 0.28 mm of MBL in patients with a cCI ≥ 2 may not be clinically relevant.
2019
34
4
992
998
Influence of crown-to-implant ratio on long-term marginal bone loss around short implants / Di Fiore, A.; Vigolo, P.; Sivolella, S.; Cavallin, F.; Katsoulis, J.; Monaco, C.; Stellini, E.. - In: INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS. - ISSN 0882-2786. - 34:4(2019), pp. 992-998. [10.11607/jomi.7161]
Di Fiore, A.; Vigolo, P.; Sivolella, S.; Cavallin, F.; Katsoulis, J.; Monaco, C.; Stellini, E.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1281222
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 16
social impact