Background: Cardiac implantable electronic devices (CIEDs) are widely used according to consensus guidelines in various patient categories. The longevity of CIED is a major determinant of the frequency with which patients require device replacement. Given the mismatch between the useful life of the devices and patient survival, device replacement is often needed. There is a great variability in the criteria used by manufacturers to determine the longevity of pacemakers (PM), implantable defibrillators (ICDs), and devices for cardiac resynchronization therapy (CRT). Thus, a fair comparison and an effective device evaluation is often difficult. Methods: The objective of this paper is to provide standardized criteria based on typical clinical settings for estimating the longevity of single and dual chamber ICDs, cardiac resynchronization defibrillators (CRT-D), single and dual chamber PMs, and cardiac resynchronization PMs (CRT- P) to be used in health technology assessment for an appropriate comparison among different devices. Results: The proposed parameters, if applied to the current marketed devices, provide longevity values in the range 5–17.2 years. Conclusion: The values of longevity with the non-standardized criteria used by the manufacturers result in higher maximum values respect to the proposed standardized criteria for CRT-D, CRTD-MPP, CRT-P, and Dual-chamber PM.

Estimate and reporting of longevity for cardiac implantable electronic devices: a proposal for standardized criteria / Censi, F.; Calcagnini, G.; Mattei, E.; Ricci, R. P.; Zoni Berisso, M.; Landolina, M.; Boriani, G.. - In: EXPERT REVIEW OF MEDICAL DEVICES. - ISSN 1743-4440. - 18:12(2021), pp. 1203-1208. [10.1080/17434440.2021.2013199]

Estimate and reporting of longevity for cardiac implantable electronic devices: a proposal for standardized criteria

Boriani G.
2021

Abstract

Background: Cardiac implantable electronic devices (CIEDs) are widely used according to consensus guidelines in various patient categories. The longevity of CIED is a major determinant of the frequency with which patients require device replacement. Given the mismatch between the useful life of the devices and patient survival, device replacement is often needed. There is a great variability in the criteria used by manufacturers to determine the longevity of pacemakers (PM), implantable defibrillators (ICDs), and devices for cardiac resynchronization therapy (CRT). Thus, a fair comparison and an effective device evaluation is often difficult. Methods: The objective of this paper is to provide standardized criteria based on typical clinical settings for estimating the longevity of single and dual chamber ICDs, cardiac resynchronization defibrillators (CRT-D), single and dual chamber PMs, and cardiac resynchronization PMs (CRT- P) to be used in health technology assessment for an appropriate comparison among different devices. Results: The proposed parameters, if applied to the current marketed devices, provide longevity values in the range 5–17.2 years. Conclusion: The values of longevity with the non-standardized criteria used by the manufacturers result in higher maximum values respect to the proposed standardized criteria for CRT-D, CRTD-MPP, CRT-P, and Dual-chamber PM.
2021
18
12
1203
1208
Estimate and reporting of longevity for cardiac implantable electronic devices: a proposal for standardized criteria / Censi, F.; Calcagnini, G.; Mattei, E.; Ricci, R. P.; Zoni Berisso, M.; Landolina, M.; Boriani, G.. - In: EXPERT REVIEW OF MEDICAL DEVICES. - ISSN 1743-4440. - 18:12(2021), pp. 1203-1208. [10.1080/17434440.2021.2013199]
Censi, F.; Calcagnini, G.; Mattei, E.; Ricci, R. P.; Zoni Berisso, M.; Landolina, M.; Boriani, G.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1279266
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact