Background: The incidence of infections associated with cardiac implantable electronic devices (CIEDs) and patient outcomes are not fully known. Aim: To provide a contemporary assessment of the risk of CIEDs infection and associated clinical outcomes. Methods: In Italy, 18 centres enrolled all consecutive patients undergoing a CIED procedure and entered a 12-months follow-up. CIED infections, as well as a composite clinical event of infection or all-cause death were recorded. Results: A total of 2675 patients (64.3% male, age 78 (70–84)) were enrolled. During follow up 28 (1.1%) CIED infections and 132 (5%) deaths, with 152 (5.7%) composite clinical events were observed. At a multivariate analysis, the type of procedure (revision/upgrading/reimplantation) (OR: 4.08, 95% CI: 1.38–12.08) and diabetes (OR: 2.22, 95% CI: 1.02–4.84) were found as main clinical factors associated to CIED infection. Both the PADIT score and the RI-AIAC Infection score were significantly associated with CIED infections, with the RI-AIAC infection score showing the strongest association (OR: 2.38, 95% CI: 1.60–3.55 for each point), with a c-index = 0.64 (0.52–0.75), p = 0.015. Regarding the occurrence of composite clinical events, the Kolek score, the Shariff score and the RI-AIAC Event score all predicted the outcome, with an AUC for the RI-AIAC Event score equal to 0.67 (0.63−0.71) p < 0.001. Conclusions: In this Italian nationwide cohort of patients, while the incidence of CIED infections was substantially low, the rate of the composite clinical outcome of infection or all-cause death was quite high and associated with several clinical factors depicting a more impaired clinical status.

Incidence and Predictors of Infections and All-Cause Death in Patients with Cardiac Implantable Electronic Devices: The Italian Nationwide RI-AIAC Registry / Boriani, G.; Proietti, M.; Bertini, M.; Diemberger, I.; Palmisano, P.; Baccarini, S.; Biscione, F.; Bottoni, N.; Ciccaglioni, A.; Monte, A. D.; Ferrari, F. A.; Iacopino, S.; Piacenti, M.; Porcelli, D.; Sangiorgio, S.; Santini, L.; Malagu, M.; Stabile, G.; Imberti, J. F.; Caruso, D.; Zoni-Berisso, M.; De Ponti, R.; Ricci, R. P.. - In: JOURNAL OF PERSONALIZED MEDICINE. - ISSN 2075-4426. - 12:1(2022), pp. 1-16. [10.3390/jpm12010091]

Incidence and Predictors of Infections and All-Cause Death in Patients with Cardiac Implantable Electronic Devices: The Italian Nationwide RI-AIAC Registry

Boriani G.;Imberti J. F.;
2022

Abstract

Background: The incidence of infections associated with cardiac implantable electronic devices (CIEDs) and patient outcomes are not fully known. Aim: To provide a contemporary assessment of the risk of CIEDs infection and associated clinical outcomes. Methods: In Italy, 18 centres enrolled all consecutive patients undergoing a CIED procedure and entered a 12-months follow-up. CIED infections, as well as a composite clinical event of infection or all-cause death were recorded. Results: A total of 2675 patients (64.3% male, age 78 (70–84)) were enrolled. During follow up 28 (1.1%) CIED infections and 132 (5%) deaths, with 152 (5.7%) composite clinical events were observed. At a multivariate analysis, the type of procedure (revision/upgrading/reimplantation) (OR: 4.08, 95% CI: 1.38–12.08) and diabetes (OR: 2.22, 95% CI: 1.02–4.84) were found as main clinical factors associated to CIED infection. Both the PADIT score and the RI-AIAC Infection score were significantly associated with CIED infections, with the RI-AIAC infection score showing the strongest association (OR: 2.38, 95% CI: 1.60–3.55 for each point), with a c-index = 0.64 (0.52–0.75), p = 0.015. Regarding the occurrence of composite clinical events, the Kolek score, the Shariff score and the RI-AIAC Event score all predicted the outcome, with an AUC for the RI-AIAC Event score equal to 0.67 (0.63−0.71) p < 0.001. Conclusions: In this Italian nationwide cohort of patients, while the incidence of CIED infections was substantially low, the rate of the composite clinical outcome of infection or all-cause death was quite high and associated with several clinical factors depicting a more impaired clinical status.
2022
12
1
1
16
Incidence and Predictors of Infections and All-Cause Death in Patients with Cardiac Implantable Electronic Devices: The Italian Nationwide RI-AIAC Registry / Boriani, G.; Proietti, M.; Bertini, M.; Diemberger, I.; Palmisano, P.; Baccarini, S.; Biscione, F.; Bottoni, N.; Ciccaglioni, A.; Monte, A. D.; Ferrari, F. A.; Iacopino, S.; Piacenti, M.; Porcelli, D.; Sangiorgio, S.; Santini, L.; Malagu, M.; Stabile, G.; Imberti, J. F.; Caruso, D.; Zoni-Berisso, M.; De Ponti, R.; Ricci, R. P.. - In: JOURNAL OF PERSONALIZED MEDICINE. - ISSN 2075-4426. - 12:1(2022), pp. 1-16. [10.3390/jpm12010091]
Boriani, G.; Proietti, M.; Bertini, M.; Diemberger, I.; Palmisano, P.; Baccarini, S.; Biscione, F.; Bottoni, N.; Ciccaglioni, A.; Monte, A. D.; Ferrari, F. A.; Iacopino, S.; Piacenti, M.; Porcelli, D.; Sangiorgio, S.; Santini, L.; Malagu, M.; Stabile, G.; Imberti, J. F.; Caruso, D.; Zoni-Berisso, M.; De Ponti, R.; Ricci, R. P.
File in questo prodotto:
File Dimensione Formato  
jpm-12-00091.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1279246
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 15
social impact