Successful translation of organic transistors as sensors and transducers to clinical settings is hampered by safety and stability issues. The operation of such devices demands driving voltages across the biotic/abiotic interface, which may result in undesired electrochemical reactions that may harm both the patient and the device. In this study, a novel operational mode is presented for electrolyte-gated organic transistors that avoid these drawbacks: the common-drain/grounded-source configuration. This approach reverts the standard common-source/common-ground configuration and achieves maximum signal amplification while applying null net bias across the electrolyte, with no parasitic currents. The viability of the proposed configuration is demonstrated by recording in vivo the somatosensory evoked activity from the barrel cortex of rats. The main inherent advantage of transistors with respect to passive electrodes is preserved in the proposed scheme: a superior signal-to-noise ratio is achieved which enables the detection of evoked activity at the single-trial level. Then, common-drain/grounded-source organic transistors are proposed as ideal candidate devices for a harmless translational recording platform.

A Novel Biasing Scheme of Electrolyte-Gated Organic Transistors for Safe In Vivo Amplification of Electrophysiological Signals / Di Lauro, M.; Zucchini, E.; De Salvo, A.; Delfino, E.; Bianchi, M.; Murgia, M.; Carli, S.; Biscarini, F.; Fadiga, L.. - In: ADVANCED MATERIALS INTERFACES. - ISSN 2196-7350. - 9:11(2022), pp. 2101798-N/A. [10.1002/admi.202101798]

A Novel Biasing Scheme of Electrolyte-Gated Organic Transistors for Safe In Vivo Amplification of Electrophysiological Signals

Bianchi M.
Membro del Collaboration Group
;
Biscarini F.
Supervision
;
2022

Abstract

Successful translation of organic transistors as sensors and transducers to clinical settings is hampered by safety and stability issues. The operation of such devices demands driving voltages across the biotic/abiotic interface, which may result in undesired electrochemical reactions that may harm both the patient and the device. In this study, a novel operational mode is presented for electrolyte-gated organic transistors that avoid these drawbacks: the common-drain/grounded-source configuration. This approach reverts the standard common-source/common-ground configuration and achieves maximum signal amplification while applying null net bias across the electrolyte, with no parasitic currents. The viability of the proposed configuration is demonstrated by recording in vivo the somatosensory evoked activity from the barrel cortex of rats. The main inherent advantage of transistors with respect to passive electrodes is preserved in the proposed scheme: a superior signal-to-noise ratio is achieved which enables the detection of evoked activity at the single-trial level. Then, common-drain/grounded-source organic transistors are proposed as ideal candidate devices for a harmless translational recording platform.
2022
9
11
2101798
N/A
A Novel Biasing Scheme of Electrolyte-Gated Organic Transistors for Safe In Vivo Amplification of Electrophysiological Signals / Di Lauro, M.; Zucchini, E.; De Salvo, A.; Delfino, E.; Bianchi, M.; Murgia, M.; Carli, S.; Biscarini, F.; Fadiga, L.. - In: ADVANCED MATERIALS INTERFACES. - ISSN 2196-7350. - 9:11(2022), pp. 2101798-N/A. [10.1002/admi.202101798]
Di Lauro, M.; Zucchini, E.; De Salvo, A.; Delfino, E.; Bianchi, M.; Murgia, M.; Carli, S.; Biscarini, F.; Fadiga, L.
File in questo prodotto:
File Dimensione Formato  
Manuscript_marked_revisions.pdf

Open access

Tipologia: Versione originale dell'autore proposta per la pubblicazione
Dimensione 2.16 MB
Formato Adobe PDF
2.16 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1270580
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 7
social impact