Purpose: To compare the 2D and 3D positional accuracy of four guided surgical protocols using an analysis of linear and angular deviations. Methods: DICOM and.STLs files obtained from a CBCT and a digital impression were superimposed with software to plan implant position. Fifty-six patients were subdivided into 4 groups: FGA group (template support [Ts]: teeth [T]; bed preparation [Bp]: fully guided [FG]; implant insertion [Ii]: 3D template [3Dt]; device [D]: manual adapter [MA], FGM group (Ts: T; Bp: FG; Ii: 3Dt; D: fully guided mounter [FGM]), PG group (Ts: T; Bp: FG; Ii: manual; D: none) and MS group (Ts: mucosa; Bp: FG; Ii: 3Dt; D: FGM). The position of 120 implants was assessed by superimposing the planned and final position recorded with a digital impression. Results: In FGA group, 3D deviations were 0.92 ± 0.52 mm at the implant head and 1.14 ± 0.54 mm at the apex, and the angular deviation (ang. dev.) was 2.45 ± 1.24°. In FGM group, were 0.911 ± 0.44 mm (head) and 1.11 ± 0.54 mm (apex), and the ang. dev. was 2.73 ± 1.96°. In PG group, were 0.95 ± 0.47 mm (head) and 1.17 ± 0.488 mm (apex), and the ang. dev. was 3.71 ± 1.67°. In MS group, were 1.15 ± 0.45 mm (head) and 1.42 ± 0.45 mm (apex), and the ang. dev. was 4.19 ± 2.62°. Ang. dev. of MS group was different from the other groups (P < 0.05). Conclusions: Guided surgery showed a sufficient accuracy.

2D/3D accuracies of implant position after guided surgery using different surgical protocols: A retrospective study / Monaco, C.; Arena, A.; Corsaletti, L.; Santomauro, V.; Venezia, P.; Cavalcanti, R.; Di Fiore, A.; Zucchelli, G.. - In: JOURNAL OF PROSTHODONTIC RESEARCH. - ISSN 1883-1958. - 64:4(2020), pp. 424-430. [10.1016/j.jpor.2019.11.007]

2D/3D accuracies of implant position after guided surgery using different surgical protocols: A retrospective study

Monaco C.;
2020

Abstract

Purpose: To compare the 2D and 3D positional accuracy of four guided surgical protocols using an analysis of linear and angular deviations. Methods: DICOM and.STLs files obtained from a CBCT and a digital impression were superimposed with software to plan implant position. Fifty-six patients were subdivided into 4 groups: FGA group (template support [Ts]: teeth [T]; bed preparation [Bp]: fully guided [FG]; implant insertion [Ii]: 3D template [3Dt]; device [D]: manual adapter [MA], FGM group (Ts: T; Bp: FG; Ii: 3Dt; D: fully guided mounter [FGM]), PG group (Ts: T; Bp: FG; Ii: manual; D: none) and MS group (Ts: mucosa; Bp: FG; Ii: 3Dt; D: FGM). The position of 120 implants was assessed by superimposing the planned and final position recorded with a digital impression. Results: In FGA group, 3D deviations were 0.92 ± 0.52 mm at the implant head and 1.14 ± 0.54 mm at the apex, and the angular deviation (ang. dev.) was 2.45 ± 1.24°. In FGM group, were 0.911 ± 0.44 mm (head) and 1.11 ± 0.54 mm (apex), and the ang. dev. was 2.73 ± 1.96°. In PG group, were 0.95 ± 0.47 mm (head) and 1.17 ± 0.488 mm (apex), and the ang. dev. was 3.71 ± 1.67°. In MS group, were 1.15 ± 0.45 mm (head) and 1.42 ± 0.45 mm (apex), and the ang. dev. was 4.19 ± 2.62°. Ang. dev. of MS group was different from the other groups (P < 0.05). Conclusions: Guided surgery showed a sufficient accuracy.
2020
64
4
424
430
2D/3D accuracies of implant position after guided surgery using different surgical protocols: A retrospective study / Monaco, C.; Arena, A.; Corsaletti, L.; Santomauro, V.; Venezia, P.; Cavalcanti, R.; Di Fiore, A.; Zucchelli, G.. - In: JOURNAL OF PROSTHODONTIC RESEARCH. - ISSN 1883-1958. - 64:4(2020), pp. 424-430. [10.1016/j.jpor.2019.11.007]
Monaco, C.; Arena, A.; Corsaletti, L.; Santomauro, V.; Venezia, P.; Cavalcanti, R.; Di Fiore, A.; Zucchelli, G.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1883195819302713-main.pdf

Accesso riservato

Dimensione 1.35 MB
Formato Adobe PDF
1.35 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1264580
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 25