Introduction: To compare endoleak outcomes after thoracic endovascular aneurysm repair (TEVAR) with different stent-graft generations into long-term follow-up. Design: retrospective, observational, and single-center cohort study. Methods: TEVAR procedures performed between November 1995 and December 2020 were analyzed. The primary endpoint of this study was the freedom from endoleak (type I/III) in four stent-graft generations during the follow-up period. The first generation (GEN1) included: Vanguard; AneuRx and Talent; Stentor; Excluder; Endologix; EndoFit. The second generation (GEN2) included: TAG and TX. The third (GEN3) included: Relay Plus; Valiant Captivia; Zenith Alpha and custom-made. The fourth (GEN4) included: Relay Pro; Conformable C-TAG; Navion; E-Vita; Najuta; Nexus; standard and custom-made thoraco-abdominal devices. Nonaortic and aorta-related survival was considered as secondary outcome. Results: A total of 509 TEVAR were included with a 44.3 ± 42.5 months mean follow-up. Freedom from endoleak at 5 years was 65.6%, 61.4%, 76.2%, and 69.1% for GEN1, GEN2, GEN3, and GEN4, respectively (p = 0.368). The first two generations demonstrated a higher endoleak rate when compared with the two most recent ones (27.2 vs 18.2%, respectively; p = 0.043). GEN1 was an independent risk factor (p = 0.014) and GEN4 was an independent protective factor (p = 0.001) for endoleak. GEN1 was found to be a risk factor for type-Ia endoleak (p = 0.059). GEN4 demonstrated a protective association regarding type-Ib endoleak (p = 0.012). Overall survival was 75.3%, 44.4%, 27.2%, and 17.6% at 1, 5, 10, and 15 years, respectively. Survival distinguished as non-related versus aortic-related was 86.7% vs 23.5%, 52.7% vs 9.8%, 32.9% vs 2.0%, 21.2% vs 0% at 1, 5, 10, and 15 years, respectively (p< 0.000). Conclusion: Endoleak occurred in a non-negligible percentage of TEVAR patients. A significant reduction of endoleak incidence over evolving stent-grafts generations was registered. Newer stent-graft generations demonstrated better long-term endoleak. Data about long-term outcomes require ongoing updates to prove both the reliability and the durability of newer stent-graft generations.

Endoleak outcomes with different stent-graft generations in a 25-years thoracic endovascular aortic repair experience / Gennai, S.; Leone, N.; Maria Bartolotti, L. A.; Covic, T.; Lauricella, A.; Andreoli, F.; Saitta, G.; Silingardi, R.. - In: VASCULAR. - ISSN 1708-5381. - 30:6(2022), pp. 1069-1079. [10.1177/17085381211051486]

Endoleak outcomes with different stent-graft generations in a 25-years thoracic endovascular aortic repair experience

Gennai S.;Leone N.;Lauricella A.;Andreoli F.;Silingardi R.
2022

Abstract

Introduction: To compare endoleak outcomes after thoracic endovascular aneurysm repair (TEVAR) with different stent-graft generations into long-term follow-up. Design: retrospective, observational, and single-center cohort study. Methods: TEVAR procedures performed between November 1995 and December 2020 were analyzed. The primary endpoint of this study was the freedom from endoleak (type I/III) in four stent-graft generations during the follow-up period. The first generation (GEN1) included: Vanguard; AneuRx and Talent; Stentor; Excluder; Endologix; EndoFit. The second generation (GEN2) included: TAG and TX. The third (GEN3) included: Relay Plus; Valiant Captivia; Zenith Alpha and custom-made. The fourth (GEN4) included: Relay Pro; Conformable C-TAG; Navion; E-Vita; Najuta; Nexus; standard and custom-made thoraco-abdominal devices. Nonaortic and aorta-related survival was considered as secondary outcome. Results: A total of 509 TEVAR were included with a 44.3 ± 42.5 months mean follow-up. Freedom from endoleak at 5 years was 65.6%, 61.4%, 76.2%, and 69.1% for GEN1, GEN2, GEN3, and GEN4, respectively (p = 0.368). The first two generations demonstrated a higher endoleak rate when compared with the two most recent ones (27.2 vs 18.2%, respectively; p = 0.043). GEN1 was an independent risk factor (p = 0.014) and GEN4 was an independent protective factor (p = 0.001) for endoleak. GEN1 was found to be a risk factor for type-Ia endoleak (p = 0.059). GEN4 demonstrated a protective association regarding type-Ib endoleak (p = 0.012). Overall survival was 75.3%, 44.4%, 27.2%, and 17.6% at 1, 5, 10, and 15 years, respectively. Survival distinguished as non-related versus aortic-related was 86.7% vs 23.5%, 52.7% vs 9.8%, 32.9% vs 2.0%, 21.2% vs 0% at 1, 5, 10, and 15 years, respectively (p< 0.000). Conclusion: Endoleak occurred in a non-negligible percentage of TEVAR patients. A significant reduction of endoleak incidence over evolving stent-grafts generations was registered. Newer stent-graft generations demonstrated better long-term endoleak. Data about long-term outcomes require ongoing updates to prove both the reliability and the durability of newer stent-graft generations.
2022
31-dic-2021
30
6
1069
1079
Endoleak outcomes with different stent-graft generations in a 25-years thoracic endovascular aortic repair experience / Gennai, S.; Leone, N.; Maria Bartolotti, L. A.; Covic, T.; Lauricella, A.; Andreoli, F.; Saitta, G.; Silingardi, R.. - In: VASCULAR. - ISSN 1708-5381. - 30:6(2022), pp. 1069-1079. [10.1177/17085381211051486]
Gennai, S.; Leone, N.; Maria Bartolotti, L. A.; Covic, T.; Lauricella, A.; Andreoli, F.; Saitta, G.; Silingardi, R.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.