Objectives: Opioids are the preferred analgesic drugs to treat severe chronic pain conditions among dialysis patients; however, knowledge about their dialyzability features is limited. Oxycodone is increasingly used for the treatment of chronic pain conditions as oral controlled release (CR) tablets; however, evidence about this drug and its metabolites' dialyzability is lacking. Methods: We assessed, during 4-hour dialysis sessions, the effect of standard hemodialysis (HD) and online hemodiafiltration (HDF) methods on the plasma concentration of oxycodone and its metabolites in n = 20 chronic pain patients with end-stage renal disease who were stably treated with oral CR oxycodone. Chromatographic techniques were used to evaluate the studied compounds' plasma concentrations at three different time points during dialysis. Results: Mean plasma concentrations of oxycodone and noroxycodone in the sample showed an overall reduction trend over time, but it was less enhanced for noroxycodone. Mean reduction in oxycodone and noroxycodone arterial concentrations was significant and higher with HDF (54% and 27%, respectively) than with HD (22% and 17%, respectively). Analysis of the regression of these compounds' clearance on their increasing arterial concentration showed a more stable and linear clearance prediction with HDF (roughly 85 mL/min); with HD, for increasing arterial concentration, clearance of oxycodone decreased while noroxycodone clearance increased. Discussion: While no oxymorphone or noroxymorphone metabolites were detected, limited dialyzability of oxycodone and noroxycodone was documented along with insignificant postdialysis pain increment. This evidence will contribute toward considerations as to the safety of the use of oxycodone in dialysis patients in the future.

Dialyzability of Oxycodone and Its Metabolites in Chronic Noncancer Pain Patients with End-Stage Renal Disease / Samolsky Dekel, Bg; Donati, G; Vasarri, A; Croci Chiocchini, Al; Gori, A; Cavallari, G; Di Nino, G; Mercolini, L; Protti, M; Mandrioli, R; Melotti, Rm; La Manna, G. - In: PAIN PRACTICE. - ISSN 1530-7085. - 17:5(2017), pp. 604-615. [10.1111/papr.12483]

Dialyzability of Oxycodone and Its Metabolites in Chronic Noncancer Pain Patients with End-Stage Renal Disease

Donati G;
2017

Abstract

Objectives: Opioids are the preferred analgesic drugs to treat severe chronic pain conditions among dialysis patients; however, knowledge about their dialyzability features is limited. Oxycodone is increasingly used for the treatment of chronic pain conditions as oral controlled release (CR) tablets; however, evidence about this drug and its metabolites' dialyzability is lacking. Methods: We assessed, during 4-hour dialysis sessions, the effect of standard hemodialysis (HD) and online hemodiafiltration (HDF) methods on the plasma concentration of oxycodone and its metabolites in n = 20 chronic pain patients with end-stage renal disease who were stably treated with oral CR oxycodone. Chromatographic techniques were used to evaluate the studied compounds' plasma concentrations at three different time points during dialysis. Results: Mean plasma concentrations of oxycodone and noroxycodone in the sample showed an overall reduction trend over time, but it was less enhanced for noroxycodone. Mean reduction in oxycodone and noroxycodone arterial concentrations was significant and higher with HDF (54% and 27%, respectively) than with HD (22% and 17%, respectively). Analysis of the regression of these compounds' clearance on their increasing arterial concentration showed a more stable and linear clearance prediction with HDF (roughly 85 mL/min); with HD, for increasing arterial concentration, clearance of oxycodone decreased while noroxycodone clearance increased. Discussion: While no oxymorphone or noroxymorphone metabolites were detected, limited dialyzability of oxycodone and noroxycodone was documented along with insignificant postdialysis pain increment. This evidence will contribute toward considerations as to the safety of the use of oxycodone in dialysis patients in the future.
2017
17
5
604
615
Dialyzability of Oxycodone and Its Metabolites in Chronic Noncancer Pain Patients with End-Stage Renal Disease / Samolsky Dekel, Bg; Donati, G; Vasarri, A; Croci Chiocchini, Al; Gori, A; Cavallari, G; Di Nino, G; Mercolini, L; Protti, M; Mandrioli, R; Melotti, Rm; La Manna, G. - In: PAIN PRACTICE. - ISSN 1530-7085. - 17:5(2017), pp. 604-615. [10.1111/papr.12483]
Samolsky Dekel, Bg; Donati, G; Vasarri, A; Croci Chiocchini, Al; Gori, A; Cavallari, G; Di Nino, G; Mercolini, L; Protti, M; Mandrioli, R; Melotti, Rm; La Manna, G
File in questo prodotto:
File Dimensione Formato  
Ossicodone articolo.pdf

Accesso riservato

Dimensione 250.05 kB
Formato Adobe PDF
250.05 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1256451
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact