We evaluate the low-dose performance of parallel nano-beam diffraction (NBD) in the transmission electron microscope as a method for characterizing radiation sensitive materials at low electron irradiation dose. A criterion, analogous to Rose's, is established for detecting a diffraction spot with desired signal-to-noise ratio. Our experimental data show that a dose substantially lower than in high-resolution bright-field imaging is sufficient to determine structure and orientation of individual nanoscale objects embedded in amorphous matrix. In an instrument equipped with a cold field-emission gun it is possible to form a probe with sub-3 nm diameter and sub-0.3 mrad convergence angle with sufficient beam current to record a diffraction pattern with less than 0.2 s acquisition time. The interpretation of NBD patterns is identical to that of selected area diffraction patterns. We illustrate the physical principles underlying good low-dose performance of NBD by means of a phase grating. The electron irradiation dose needed to detect a diffraction peak in NBD is found proportional to 1/N(2), where N is the number of lattice planes contributing to the peak. (C) 2008 Elsevier B.V. All rights reserved.
Low-dose performance of parallel-beam nanodiffraction / Malac, M; Beleggia, M; Taniguchi, Y; Egerton, Rf; Zhu, Y. - In: ULTRAMICROSCOPY. - ISSN 0304-3991. - 109:1(2008), pp. 14-21. [10.1016/j.ultramic.2008.07.004]
Low-dose performance of parallel-beam nanodiffraction
Beleggia M;
2008
Abstract
We evaluate the low-dose performance of parallel nano-beam diffraction (NBD) in the transmission electron microscope as a method for characterizing radiation sensitive materials at low electron irradiation dose. A criterion, analogous to Rose's, is established for detecting a diffraction spot with desired signal-to-noise ratio. Our experimental data show that a dose substantially lower than in high-resolution bright-field imaging is sufficient to determine structure and orientation of individual nanoscale objects embedded in amorphous matrix. In an instrument equipped with a cold field-emission gun it is possible to form a probe with sub-3 nm diameter and sub-0.3 mrad convergence angle with sufficient beam current to record a diffraction pattern with less than 0.2 s acquisition time. The interpretation of NBD patterns is identical to that of selected area diffraction patterns. We illustrate the physical principles underlying good low-dose performance of NBD by means of a phase grating. The electron irradiation dose needed to detect a diffraction peak in NBD is found proportional to 1/N(2), where N is the number of lattice planes contributing to the peak. (C) 2008 Elsevier B.V. All rights reserved.Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris