The evolution of robotic technology and its diffusion does not seem to have been adequately accompanied by the development and implementation of surgeon training programs that ensure skilled and safe device use at the start of the learning curve. The objective of the study is to develop and validate performance metrics for vessel dissection, vessel loop positioning, clip applying and bipolar coagulation using an avian model. Three robotic surgeons and a behavioral scientist characterized the performance metrics of the task according to the proficiency-based progression methodology. Fourteen experienced robotic surgeons from different European countries participated in a modified online Delphi consensus. Eight experienced surgeons and eight novices performed the robotic task twice. In the Delphi meeting, 100% consensus was reached on the performance metrics. Novice surgeons took 26 min to complete the entire task on trial 1 and 20 min on trial 2. Experts took 10.1 min and 9.5 min. On average the Expert Group completed the task 137% faster than the Novice Group. The amount of time to reach the vessel part of the task was also calculated. Novice surgeons took 26 min on trial 1 and 20 min on trial 2. Experts took 5.5 min and 4.8 min. On average the experts reached the vessel 200% faster than the novices. The Expert Group made 155% fewer performance errors than the Novice Group. The mean IRR of video-recorded performance assessments for all metrics was 0.96 (95% confidence intervals (CI) lower = 0.94–upper = 0.98). We report the development and validation for a standard and replicable basic robotic vessel dissection, vessel loop positioning, clip applying and bipolar coagulation task on an avian model. The development of objective performance metrics, based on a transparent and fair methodology (i.e., PBP), is the first fundamental step toward quality assured training. This task developed on the avian model proved to have good results in the validation study.

Development and validation of the metric-based assessment of a robotic vessel dissection, vessel loop positioning, clip applying and bipolar coagulation task on an avian model / Puliatti, S.; Amato, M.; Mazzone, E.; Rosiello, G.; De Groote, R.; Piazza, P.; Sarchi, L.; Farinha, R.; Mottrie, A.; Gallagher, A. G.. - In: JOURNAL OF ROBOTIC SURGERY. - ISSN 1863-2483. - 16:3(2022), pp. 677-685. [10.1007/s11701-021-01293-6]

Development and validation of the metric-based assessment of a robotic vessel dissection, vessel loop positioning, clip applying and bipolar coagulation task on an avian model

Puliatti S.;Amato M.;Sarchi L.;
2022

Abstract

The evolution of robotic technology and its diffusion does not seem to have been adequately accompanied by the development and implementation of surgeon training programs that ensure skilled and safe device use at the start of the learning curve. The objective of the study is to develop and validate performance metrics for vessel dissection, vessel loop positioning, clip applying and bipolar coagulation using an avian model. Three robotic surgeons and a behavioral scientist characterized the performance metrics of the task according to the proficiency-based progression methodology. Fourteen experienced robotic surgeons from different European countries participated in a modified online Delphi consensus. Eight experienced surgeons and eight novices performed the robotic task twice. In the Delphi meeting, 100% consensus was reached on the performance metrics. Novice surgeons took 26 min to complete the entire task on trial 1 and 20 min on trial 2. Experts took 10.1 min and 9.5 min. On average the Expert Group completed the task 137% faster than the Novice Group. The amount of time to reach the vessel part of the task was also calculated. Novice surgeons took 26 min on trial 1 and 20 min on trial 2. Experts took 5.5 min and 4.8 min. On average the experts reached the vessel 200% faster than the novices. The Expert Group made 155% fewer performance errors than the Novice Group. The mean IRR of video-recorded performance assessments for all metrics was 0.96 (95% confidence intervals (CI) lower = 0.94–upper = 0.98). We report the development and validation for a standard and replicable basic robotic vessel dissection, vessel loop positioning, clip applying and bipolar coagulation task on an avian model. The development of objective performance metrics, based on a transparent and fair methodology (i.e., PBP), is the first fundamental step toward quality assured training. This task developed on the avian model proved to have good results in the validation study.
2022
12-ago-2021
16
3
677
685
Development and validation of the metric-based assessment of a robotic vessel dissection, vessel loop positioning, clip applying and bipolar coagulation task on an avian model / Puliatti, S.; Amato, M.; Mazzone, E.; Rosiello, G.; De Groote, R.; Piazza, P.; Sarchi, L.; Farinha, R.; Mottrie, A.; Gallagher, A. G.. - In: JOURNAL OF ROBOTIC SURGERY. - ISSN 1863-2483. - 16:3(2022), pp. 677-685. [10.1007/s11701-021-01293-6]
Puliatti, S.; Amato, M.; Mazzone, E.; Rosiello, G.; De Groote, R.; Piazza, P.; Sarchi, L.; Farinha, R.; Mottrie, A.; Gallagher, A. G.
File in questo prodotto:
File Dimensione Formato  
Development and validation of the metric‑based assessment of a robotic vessel dissection, vessel loop positioning, clip applying and bipolar coagulation task on an avian model.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 1.25 MB
Formato Adobe PDF
1.25 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1252406
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 6
social impact