Purpose: To evaluate intravascular ultrasound (IVUS) safety and efficacy to detect visceral stenting issues during complex endovascular aneurysm repair through branched and fenestrated repair (B-FEVAR). Materials and Methods: A single-center retrospective analysis of 33 bridging stents assessed intraoperatively using IVUS between January and September 2020 was performed. Ten aortic aneurysm patients [7 thoracoabdominal / 1 pararenal / 2 juxtarenal; 3 females; mean age 73 years [range 70–77 years]) were included. Eight BEVAR (5 standard; 2 custom-made) and 2 FEVAR (custom-made) were performed. The study assessed the safety and efficacy of IVUS utilization to detect immediate branch instability after visceral stenting in the case of B-FEVAR. The primary safety endpoint was defined as the absence of IVUS-related adverse events. The primary efficacy endpoint was defined as the composite of technical success of the IVUS-assessment in each target visceral vessels (TVVs), the rate of IVUS-findings divided as prompting additional maneuvers or not, and the incidence of postoperative computed tomography angiography findings compared with intraoperative assessment. Results: There were no IVUS-related adverse events. The technical success of the IVUS-assessment was achieved in all TVVs. No technical issues compromised the evaluation of the intended vessel. Among the 7 findings identified by IVUS, 3 were suspected at the angiography. In all, 57% (4/7) had normal final angiography. IVUS was able to detect a 12% (4/33) intraoperative branch instability not identified/suspected at the completion angiography. The IVUS assessment led to an immediate revision in 5 (15%) vessels. A total of 57% (4/7) of the issues were detected in patients undergoing primary BEVAR. The remaining 43% (3/7) was detected in patients undergoing secondary intervention for branch instability. Conclusion: IVUS was safe as an adjunctive imaging technique to assess completion after B-FEVAR. It demonstrated efficacy in the detection of intraoperative issues missed by angiography. Further investigations are required to validate these promising results.

Intravascular Ultrasound in Branched and Fenestrated Endovascular Aneurysm Repair: Initial Experience in a Single-Center Cohort Study / Gennai, S.; Leone, N.; Saitta, G.; Migliari, M.; Lauricella, A.; Farchioni, L.; Silingardi, R.. - In: JOURNAL OF ENDOVASCULAR THERAPY. - ISSN 1526-6028. - 28:6(2021), pp. 828-836. [10.1177/15266028211025014]

Intravascular Ultrasound in Branched and Fenestrated Endovascular Aneurysm Repair: Initial Experience in a Single-Center Cohort Study

Gennai S.;Leone N.;Lauricella A.;Silingardi R.
2021

Abstract

Purpose: To evaluate intravascular ultrasound (IVUS) safety and efficacy to detect visceral stenting issues during complex endovascular aneurysm repair through branched and fenestrated repair (B-FEVAR). Materials and Methods: A single-center retrospective analysis of 33 bridging stents assessed intraoperatively using IVUS between January and September 2020 was performed. Ten aortic aneurysm patients [7 thoracoabdominal / 1 pararenal / 2 juxtarenal; 3 females; mean age 73 years [range 70–77 years]) were included. Eight BEVAR (5 standard; 2 custom-made) and 2 FEVAR (custom-made) were performed. The study assessed the safety and efficacy of IVUS utilization to detect immediate branch instability after visceral stenting in the case of B-FEVAR. The primary safety endpoint was defined as the absence of IVUS-related adverse events. The primary efficacy endpoint was defined as the composite of technical success of the IVUS-assessment in each target visceral vessels (TVVs), the rate of IVUS-findings divided as prompting additional maneuvers or not, and the incidence of postoperative computed tomography angiography findings compared with intraoperative assessment. Results: There were no IVUS-related adverse events. The technical success of the IVUS-assessment was achieved in all TVVs. No technical issues compromised the evaluation of the intended vessel. Among the 7 findings identified by IVUS, 3 were suspected at the angiography. In all, 57% (4/7) had normal final angiography. IVUS was able to detect a 12% (4/33) intraoperative branch instability not identified/suspected at the completion angiography. The IVUS assessment led to an immediate revision in 5 (15%) vessels. A total of 57% (4/7) of the issues were detected in patients undergoing primary BEVAR. The remaining 43% (3/7) was detected in patients undergoing secondary intervention for branch instability. Conclusion: IVUS was safe as an adjunctive imaging technique to assess completion after B-FEVAR. It demonstrated efficacy in the detection of intraoperative issues missed by angiography. Further investigations are required to validate these promising results.
2021
28
6
828
836
Intravascular Ultrasound in Branched and Fenestrated Endovascular Aneurysm Repair: Initial Experience in a Single-Center Cohort Study / Gennai, S.; Leone, N.; Saitta, G.; Migliari, M.; Lauricella, A.; Farchioni, L.; Silingardi, R.. - In: JOURNAL OF ENDOVASCULAR THERAPY. - ISSN 1526-6028. - 28:6(2021), pp. 828-836. [10.1177/15266028211025014]
Gennai, S.; Leone, N.; Saitta, G.; Migliari, M.; Lauricella, A.; Farchioni, L.; Silingardi, R.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1252228
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact