OBJECTIVE: To compare the outcomes (auditory threshold and open-set speech perception at 48-month follow-up) of a new near-field monitoring procedure, electrical compound action potential, on positioning the auditory brainstem implant electrode array on the surface of the cochlear nuclei versus the traditional far-field electrical auditory brainstem response. STUDY DESIGN: Retrospective study. SETTING: Tertiary referral center. SUBJECTS AND METHODS: Among the 202 patients with auditory brainstem implants fitted and monitored with electrical auditory brainstem response during implant fitting, 9 also underwent electrical compound action potential recording. These subjects were matched retrospectively with a control group of 9 patients in whom only the electrical auditory brainstem response was recorded. Electrical compound action potentials were obtained using a cotton-wick recording electrode located near the surface of the cochlear nuclei and on several cranial nerves. RESULTS: Significantly lower potential thresholds were observed with the recording electrode located on the cochlear nuclei surface compared with the electrical auditory brainstem response (104.4 ± 32.5 vs 158.9 ± 24.2, P = .0030). Electrical brainstem response and compound action potentials identified effects on the neighboring cranial nerves on 3.2 ± 2.4 and 7.8 ± 3.2 electrodes, respectively (P = .0034). Open-set speech perception outcomes at 48-month follow-up had improved significantly in the near- versus far-field recording groups (78.9% versus 56.7%; P = .0051). CONCLUSIONS: Electrical compound action potentials during auditory brainstem implantation significantly improved the definition of the potential threshold and the number of auditory and extra-auditory waves generated. It led to the best coupling between the electrode array and cochlear nuclei, significantly improving the overall open-set speech perception.

Improved outcomes in auditory brainstem implantation with the use of near-field electrical compound action potentials / Mandalà, M.; Colletti, L.; Colletti, G.; Colletti, V.. - In: OTOLARYNGOLOGY-HEAD AND NECK SURGERY. - ISSN 0194-5998. - 151:6(2014), pp. 1008-1013. [10.1177/0194599814551151]

Improved outcomes in auditory brainstem implantation with the use of near-field electrical compound action potentials

G. Colletti;
2014

Abstract

OBJECTIVE: To compare the outcomes (auditory threshold and open-set speech perception at 48-month follow-up) of a new near-field monitoring procedure, electrical compound action potential, on positioning the auditory brainstem implant electrode array on the surface of the cochlear nuclei versus the traditional far-field electrical auditory brainstem response. STUDY DESIGN: Retrospective study. SETTING: Tertiary referral center. SUBJECTS AND METHODS: Among the 202 patients with auditory brainstem implants fitted and monitored with electrical auditory brainstem response during implant fitting, 9 also underwent electrical compound action potential recording. These subjects were matched retrospectively with a control group of 9 patients in whom only the electrical auditory brainstem response was recorded. Electrical compound action potentials were obtained using a cotton-wick recording electrode located near the surface of the cochlear nuclei and on several cranial nerves. RESULTS: Significantly lower potential thresholds were observed with the recording electrode located on the cochlear nuclei surface compared with the electrical auditory brainstem response (104.4 ± 32.5 vs 158.9 ± 24.2, P = .0030). Electrical brainstem response and compound action potentials identified effects on the neighboring cranial nerves on 3.2 ± 2.4 and 7.8 ± 3.2 electrodes, respectively (P = .0034). Open-set speech perception outcomes at 48-month follow-up had improved significantly in the near- versus far-field recording groups (78.9% versus 56.7%; P = .0051). CONCLUSIONS: Electrical compound action potentials during auditory brainstem implantation significantly improved the definition of the potential threshold and the number of auditory and extra-auditory waves generated. It led to the best coupling between the electrode array and cochlear nuclei, significantly improving the overall open-set speech perception.
2014
151
6
1008
1013
Improved outcomes in auditory brainstem implantation with the use of near-field electrical compound action potentials / Mandalà, M.; Colletti, L.; Colletti, G.; Colletti, V.. - In: OTOLARYNGOLOGY-HEAD AND NECK SURGERY. - ISSN 0194-5998. - 151:6(2014), pp. 1008-1013. [10.1177/0194599814551151]
Mandalà, M.; Colletti, L.; Colletti, G.; Colletti, V.
File in questo prodotto:
File Dimensione Formato  
Improved Outcoomes in Auditory Brainstem Implantation with the Use of Near-Field Compund Action Potentials 2014.pdf

Accesso riservato

Dimensione 3.92 MB
Formato Adobe PDF
3.92 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
0194599814551151.pdf

Accesso riservato

Dimensione 3.87 MB
Formato Adobe PDF
3.87 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
improved outcomes.pdf

Accesso riservato

Dimensione 3.88 MB
Formato Adobe PDF
3.88 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1251958
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 0
social impact