Objective: Study the interchangeability of Roche Elecsys and Beckman Coulter Access anti-Müllerian Hormone (AMH) assays to select the gonadotropin starting dose in IVF cycles. Methods: Patients’ AMH was measured using both Elecsys and Access automated assays. AMH values were then used to calculate the FSH starting dose. The main outcome is the percentage of women that would have been stratified to a different dose of gonadotropin due to differences in AMH values from the two tests. Results: The Access assay systematically gives higher values compared with the Elecsys assay (slope = 0.88). For Follitropin Alfa, the difference in starting dose was > 15% in 2/113 patients, when Access AMH was used instead of Elecsys. For Follitropin Delta the difference in the starting dose was >15% in 21/113 patients when using Access AMH. When considering women with high ovarian reserve, only 4/51 would have received a Follitropin Delta dose that exceeded a 15% difference using Access AMH as a substitute for the Elecsys value. Conclusions: The use of the Roche Elecsys or Beckman Coulter Access leads to modest differences in AMH values, which seem to little affect the calibration of FSH dose used for ovarian stimulation.

The interchangeability of two assays for the measurement of anti-Müllerian hormone when personalizing the dose of FSH in in-vitro fertilization cycles / La Marca, A.; Tolani, A. D.; Capuzzo, M.. - In: GYNECOLOGICAL ENDOCRINOLOGY. - ISSN 0951-3590. - 37:4(2021), pp. 372-376. [10.1080/09513590.2020.1810659]

The interchangeability of two assays for the measurement of anti-Müllerian hormone when personalizing the dose of FSH in in-vitro fertilization cycles

La Marca A.;Capuzzo M.
2021

Abstract

Objective: Study the interchangeability of Roche Elecsys and Beckman Coulter Access anti-Müllerian Hormone (AMH) assays to select the gonadotropin starting dose in IVF cycles. Methods: Patients’ AMH was measured using both Elecsys and Access automated assays. AMH values were then used to calculate the FSH starting dose. The main outcome is the percentage of women that would have been stratified to a different dose of gonadotropin due to differences in AMH values from the two tests. Results: The Access assay systematically gives higher values compared with the Elecsys assay (slope = 0.88). For Follitropin Alfa, the difference in starting dose was > 15% in 2/113 patients, when Access AMH was used instead of Elecsys. For Follitropin Delta the difference in the starting dose was >15% in 21/113 patients when using Access AMH. When considering women with high ovarian reserve, only 4/51 would have received a Follitropin Delta dose that exceeded a 15% difference using Access AMH as a substitute for the Elecsys value. Conclusions: The use of the Roche Elecsys or Beckman Coulter Access leads to modest differences in AMH values, which seem to little affect the calibration of FSH dose used for ovarian stimulation.
2021
37
4
372
376
The interchangeability of two assays for the measurement of anti-Müllerian hormone when personalizing the dose of FSH in in-vitro fertilization cycles / La Marca, A.; Tolani, A. D.; Capuzzo, M.. - In: GYNECOLOGICAL ENDOCRINOLOGY. - ISSN 0951-3590. - 37:4(2021), pp. 372-376. [10.1080/09513590.2020.1810659]
La Marca, A.; Tolani, A. D.; Capuzzo, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1251545
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 3
social impact