Additive manufacturing (AM) is spreading in a wide range of industrial fields. The influence of the printing parameters on the mechanical performance is still an open issue among researchers, particularly when dealing with fatigue loads, which can lead to an unexpected failure. Classical fatigue tests require a large amount of time and materials to be consumed. Compared to the traditional fatigue assessment, the thermographic method (TM) is able to derive in a very rapid way the SN curve and fatigue limit of the material monitoring its energetic release during fatigue tests. In this work, for the first time, the energetic release during fatigue test has been evaluated in specimens made of AISI 316L, obtained by SLM technique. Compared to literature data, the specimens show premature failure, even at low stress levels, with brittle fracture surfaces. The internal microstructure seems to be strictly related to the energetic release of the material.
Energy release as a parameter for fatigue design of additive manufactured metals / Santonocito, D.; Gatto, A.; Risitano, G.. - In: MATERIAL DESIGN & PROCESSING COMMUNICATIONS. - ISSN 2577-6576. - 3:4(2021), pp. 1-7. [10.1002/mdp2.255]
Energy release as a parameter for fatigue design of additive manufactured metals
Gatto A.;
2021
Abstract
Additive manufacturing (AM) is spreading in a wide range of industrial fields. The influence of the printing parameters on the mechanical performance is still an open issue among researchers, particularly when dealing with fatigue loads, which can lead to an unexpected failure. Classical fatigue tests require a large amount of time and materials to be consumed. Compared to the traditional fatigue assessment, the thermographic method (TM) is able to derive in a very rapid way the SN curve and fatigue limit of the material monitoring its energetic release during fatigue tests. In this work, for the first time, the energetic release during fatigue test has been evaluated in specimens made of AISI 316L, obtained by SLM technique. Compared to literature data, the specimens show premature failure, even at low stress levels, with brittle fracture surfaces. The internal microstructure seems to be strictly related to the energetic release of the material.File | Dimensione | Formato | |
---|---|---|---|
mdp2.255.pdf
Open access
Tipologia:
VOR - Versione pubblicata dall'editore
Dimensione
1.39 MB
Formato
Adobe PDF
|
1.39 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris