This paper proposes a 3D lumped parameter thermal network capable of estimating the temperature distribution in classical, salient-pole wound-field synchronous generators. The developed 3D lumped parameter thermal network can be used for the thermal design and/or analysis of any wound-field synchronous generator geometry, thus offering certain degrees of flexibility.As the accurate estimation of the loss distribution is critical for the accuracy of the proposed 3D lumped parameter thermal network, an electromagnetic finite element model is used in this paper as loss determination tool for an off-the-shelf 400 kVA generator considered as a case study. The simulated losses are validated against experimental measurements to safely include them in the developed network. Finally, the stator and rotor temperatures evaluated through the 3D lumped parameter thermal network are also validated by comparing them against experimental results.
3D lumped parameter thermal network for wound-field synchronous generators / Wang, Y.; Nuzzo, S.; Gerada, C.; Zhao, W.; Zhang, H.; Galea, M.. - (2021), pp. 5-9. (Intervento presentato al convegno 2021 IEEE Workshop on Electrical Machines Design, Control and Diagnosis, WEMDCD 2021 tenutosi a ita nel 2021) [10.1109/WEMDCD51469.2021.9425624].
3D lumped parameter thermal network for wound-field synchronous generators
Nuzzo S.;
2021
Abstract
This paper proposes a 3D lumped parameter thermal network capable of estimating the temperature distribution in classical, salient-pole wound-field synchronous generators. The developed 3D lumped parameter thermal network can be used for the thermal design and/or analysis of any wound-field synchronous generator geometry, thus offering certain degrees of flexibility.As the accurate estimation of the loss distribution is critical for the accuracy of the proposed 3D lumped parameter thermal network, an electromagnetic finite element model is used in this paper as loss determination tool for an off-the-shelf 400 kVA generator considered as a case study. The simulated losses are validated against experimental measurements to safely include them in the developed network. Finally, the stator and rotor temperatures evaluated through the 3D lumped parameter thermal network are also validated by comparing them against experimental results.Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris