Background and Objectives: The efficacy of picosecond laser (PSL) in the treatment of striae distensae (SD) has been recently reported; otherwise, the base for this improvement has not been clarified yet. The aim of this study is to treat long-lasting SD with PLS and to describe their in vivo morphological variations after treatment using three-dimensional (3D) imaging and reflectance confocal microscopy (RCM). Study Design/Materials and Methods: A total of 27 patients asking for treatment for SD were treated with four monthly sessions of PLS. Clinical improvement was estimated through a blinded evaluation performed by two independent dermatologists, Global Assessment Improvement Scale (GAIS), patients′ satisfaction, 3D imaging, and RCM assessments at baseline and 6 months after the last laser session. Results: Although a clinical improvement of SD was observed in 81.4% of patients according to physicians′ GAIS, only 66.6% of patients reported subjective improvement and satisfaction after treatment (P = 0.04). 3D imaging revealed a significant improvement in terms of skin texture (P < 0.001) and mean SD depth (P < 0.001). Otherwise, RCM highlighted collagen remodeling and the appearance of new dermal papillae in all the treated SD compared with baseline. Conclusions: The present study confirms that PLS represents a safe treatment option for SD; herein, we report morphological documentation of skin variations after PLS treatment. Lasers Surg. Med. © 2021 Wiley Periodicals LLC.
Picosecond Laser treatment of Striae Distensae: In vivo Evaluation of Results by 3D Analysis, Reflectance Confocal Microscopy, and Patient′s Satisfaction / Fusano, M.; Galimberti, M. G.; Bencini, M.; Guida, S.; Bencini, P. L.. - In: LASERS IN SURGERY AND MEDICINE. - ISSN 0196-8092. - 53:9(2021), pp. 1180-1185. [10.1002/lsm.23401]
Picosecond Laser treatment of Striae Distensae: In vivo Evaluation of Results by 3D Analysis, Reflectance Confocal Microscopy, and Patient′s Satisfaction
Guida S.;
2021
Abstract
Background and Objectives: The efficacy of picosecond laser (PSL) in the treatment of striae distensae (SD) has been recently reported; otherwise, the base for this improvement has not been clarified yet. The aim of this study is to treat long-lasting SD with PLS and to describe their in vivo morphological variations after treatment using three-dimensional (3D) imaging and reflectance confocal microscopy (RCM). Study Design/Materials and Methods: A total of 27 patients asking for treatment for SD were treated with four monthly sessions of PLS. Clinical improvement was estimated through a blinded evaluation performed by two independent dermatologists, Global Assessment Improvement Scale (GAIS), patients′ satisfaction, 3D imaging, and RCM assessments at baseline and 6 months after the last laser session. Results: Although a clinical improvement of SD was observed in 81.4% of patients according to physicians′ GAIS, only 66.6% of patients reported subjective improvement and satisfaction after treatment (P = 0.04). 3D imaging revealed a significant improvement in terms of skin texture (P < 0.001) and mean SD depth (P < 0.001). Otherwise, RCM highlighted collagen remodeling and the appearance of new dermal papillae in all the treated SD compared with baseline. Conclusions: The present study confirms that PLS represents a safe treatment option for SD; herein, we report morphological documentation of skin variations after PLS treatment. Lasers Surg. Med. © 2021 Wiley Periodicals LLC.Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris