In this article, we investigate an innovative solution, to implement high sampling frequency industrial control by means of networked embedded systems connected via WiFi. The basic idea relies on a co-design approach for the control application, which is then able to adapt its sampling period, as well as to tune the Wi-Fi parameters, according to the feedback coming from the network. To this end, we implemented a cross-layer architecture acting at both application and data-link layers, which features a robust frame-delay state estimator, a time-efficient communication policy, and a specific tuning of the critical protocol parameters. Suitable hardware-in-the-loop experiments have been carried out exploiting two different embedded systems available off-the-shelf. The preliminary results, obtained from an extensive experimental campaign, are encouraging since they show that the proposed architecture enables industrial control applications requiring a sampling rate up to 1000 Hz, even in presence of communication impairments.
Time-Critical Wireless Networked Embedded Systems: Feasibility and Experimental Assessment / Branz, F.; Antonello, R.; Schenato, L.; Tramarin, F.; Vitturi, S.. - In: IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS. - ISSN 1551-3203. - 16:12(2020), pp. 7732-7742. [10.1109/TII.2020.2992990]
Time-Critical Wireless Networked Embedded Systems: Feasibility and Experimental Assessment
Tramarin F.
;
2020
Abstract
In this article, we investigate an innovative solution, to implement high sampling frequency industrial control by means of networked embedded systems connected via WiFi. The basic idea relies on a co-design approach for the control application, which is then able to adapt its sampling period, as well as to tune the Wi-Fi parameters, according to the feedback coming from the network. To this end, we implemented a cross-layer architecture acting at both application and data-link layers, which features a robust frame-delay state estimator, a time-efficient communication policy, and a specific tuning of the critical protocol parameters. Suitable hardware-in-the-loop experiments have been carried out exploiting two different embedded systems available off-the-shelf. The preliminary results, obtained from an extensive experimental campaign, are encouraging since they show that the proposed architecture enables industrial control applications requiring a sampling rate up to 1000 Hz, even in presence of communication impairments.File | Dimensione | Formato | |
---|---|---|---|
Time-Critical_Wireless_Networked_Embedded_Systems_Feasibility_and_Experimental_Assessment.pdf
Accesso riservato
Tipologia:
VOR - Versione pubblicata dall'editore
Dimensione
1.94 MB
Formato
Adobe PDF
|
1.94 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
ALL_TII-19-3612.R2.pdf
Open access
Tipologia:
AAM - Versione dell'autore revisionata e accettata per la pubblicazione
Dimensione
1.75 MB
Formato
Adobe PDF
|
1.75 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris