Salient-pole synchronous generators (SG) have a long history of utilization as reliable power generation systems. Important aspects of such generators include a high power-to-weight ratio, high efficiency and a low cost per kVA output [1]. Another critical aspect is the requirement for very low harmonic content in the output voltage. Hence, it is very important to be able to model and predict the no-load voltage waveform in an accurate manner in order to be able to satisfy standards requirements, such as the permissible total harmonic distortion (THD). Also, at steady-state conditions, parasitic voltages are induced in the damper bars which lead to a current flow with associated power losses and an increase in temperatures. This paper deals with an in-detail analysis of a 4 MVA SG, whose operation is studied and compared with experimental results for validation purposes. The same platform is then used to propose innovative solutions to the existing design and operational challenges of the machine aimed at reducing ohmic loss in the damper cage and improving the output voltage THD, without reverting to disruptive techniques such as rotor and/or stator skewing.

Damper cage loss reduction and no-load voltage thd improvements in salient-pole synchronous generators / Nuzzo, S.; Galea, M.; Gerada, C.; Gerada, D.; Mebarki, A.; Brown, N. L.. - 2016:684(2016), pp. 7 .-7 .. (Intervento presentato al convegno 8th IET International Conference on Power Electronics, Machines and Drives, PEMD 2016 tenutosi a gbr nel 2016) [10.1049/cp.2016.0203].

Damper cage loss reduction and no-load voltage thd improvements in salient-pole synchronous generators

Nuzzo S.;
2016

Abstract

Salient-pole synchronous generators (SG) have a long history of utilization as reliable power generation systems. Important aspects of such generators include a high power-to-weight ratio, high efficiency and a low cost per kVA output [1]. Another critical aspect is the requirement for very low harmonic content in the output voltage. Hence, it is very important to be able to model and predict the no-load voltage waveform in an accurate manner in order to be able to satisfy standards requirements, such as the permissible total harmonic distortion (THD). Also, at steady-state conditions, parasitic voltages are induced in the damper bars which lead to a current flow with associated power losses and an increase in temperatures. This paper deals with an in-detail analysis of a 4 MVA SG, whose operation is studied and compared with experimental results for validation purposes. The same platform is then used to propose innovative solutions to the existing design and operational challenges of the machine aimed at reducing ohmic loss in the damper cage and improving the output voltage THD, without reverting to disruptive techniques such as rotor and/or stator skewing.
2016
8th IET International Conference on Power Electronics, Machines and Drives, PEMD 2016
gbr
2016
2016
7 .
7 .
Nuzzo, S.; Galea, M.; Gerada, C.; Gerada, D.; Mebarki, A.; Brown, N. L.
Damper cage loss reduction and no-load voltage thd improvements in salient-pole synchronous generators / Nuzzo, S.; Galea, M.; Gerada, C.; Gerada, D.; Mebarki, A.; Brown, N. L.. - 2016:684(2016), pp. 7 .-7 .. (Intervento presentato al convegno 8th IET International Conference on Power Electronics, Machines and Drives, PEMD 2016 tenutosi a gbr nel 2016) [10.1049/cp.2016.0203].
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1237582
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? ND
social impact