BaCKground: To assess the long-term safety and effectiveness of endovascular aneurysm repair (evar) treatment with unibody endograft deployed on aortic bifurcation (anatomical fixation). MeThods: a retrospective, observational, single-center study of patients treated from 1999 to 2002 with unibody bifurcated endograft. follow-up protocol required clinical and doppler-ultrasound at 1 and 6 months and annually thereafter, computed tomography angiography at 1-, 6- and 12-months and then every year. Primary endpoints included technical and treatment success, survival and freedom from late evar failure; secondary endpoints were freedom from late open conversion (loC), freedom from late re-interventions and endoleaks. resulTs: seventy-three patients, mean age of 73±6 years were enrolled. Median follow-up was 6±0.5 years. Technical success was 98.6% (n.=71/73; causes of failure: 1 open conversion and 1 type ib endoleak). a treatment success of 96% (n.=69/72) was recorded due to endoleaks (n.=2; 1 type ia and 1 type ib) and limb occlusion (n.=1). survival at 1, 5, 10, 15 and 18 years was 90%, 58%, 40%, 32% and 23% respectively. one aneurysm-related death for infection of the endograft was registered. evar failure was 14% (n.=10/71). Three loC were recorded and freedom from reinterventions at 1, 5, 10 and 18 years was 99%, 91%, 86% and 86%. fourteen endoleaks were recorded: ia (n.=6; 42.8%), ia+ib (n.=1; 7.1%), ib (n.=2; 14.2%) and ii (n.=5; 35.6%). four endoleaks were observed, 9 endovascular correction and 1 loC were required. endoleaks free survival of 90% at 1-year and 75% at the end of the study. aneurysm sac shrinkage was observed in 79% (n.=56/71). CONCLUSIONS: This small, retrospective cohort of anatomically fixed EVAR demonstrated long-term safety and effectiveness. The design of the unibody graft did not substantially change and newer generation should guarantee the same performance.

Twenty years outcomes in a single center experience after endovascular aneurysm repair with unibody endograft and anatomical fixation / Silingardi, R.; Andreoli, F.; saiTTa, G. M.; Leone, N.; Migliari, M.; Gennai, S.. - In: JOURNAL OF CARDIOVASCULAR SURGERY. - ISSN 0021-9509. - 61:6(2020), pp. 720-728. [10.23736/S0021-9509.19.11076-2]

Twenty years outcomes in a single center experience after endovascular aneurysm repair with unibody endograft and anatomical fixation

Silingardi R.;Gennai S.
2020

Abstract

BaCKground: To assess the long-term safety and effectiveness of endovascular aneurysm repair (evar) treatment with unibody endograft deployed on aortic bifurcation (anatomical fixation). MeThods: a retrospective, observational, single-center study of patients treated from 1999 to 2002 with unibody bifurcated endograft. follow-up protocol required clinical and doppler-ultrasound at 1 and 6 months and annually thereafter, computed tomography angiography at 1-, 6- and 12-months and then every year. Primary endpoints included technical and treatment success, survival and freedom from late evar failure; secondary endpoints were freedom from late open conversion (loC), freedom from late re-interventions and endoleaks. resulTs: seventy-three patients, mean age of 73±6 years were enrolled. Median follow-up was 6±0.5 years. Technical success was 98.6% (n.=71/73; causes of failure: 1 open conversion and 1 type ib endoleak). a treatment success of 96% (n.=69/72) was recorded due to endoleaks (n.=2; 1 type ia and 1 type ib) and limb occlusion (n.=1). survival at 1, 5, 10, 15 and 18 years was 90%, 58%, 40%, 32% and 23% respectively. one aneurysm-related death for infection of the endograft was registered. evar failure was 14% (n.=10/71). Three loC were recorded and freedom from reinterventions at 1, 5, 10 and 18 years was 99%, 91%, 86% and 86%. fourteen endoleaks were recorded: ia (n.=6; 42.8%), ia+ib (n.=1; 7.1%), ib (n.=2; 14.2%) and ii (n.=5; 35.6%). four endoleaks were observed, 9 endovascular correction and 1 loC were required. endoleaks free survival of 90% at 1-year and 75% at the end of the study. aneurysm sac shrinkage was observed in 79% (n.=56/71). CONCLUSIONS: This small, retrospective cohort of anatomically fixed EVAR demonstrated long-term safety and effectiveness. The design of the unibody graft did not substantially change and newer generation should guarantee the same performance.
2020
18-nov-2019
61
6
720
728
Twenty years outcomes in a single center experience after endovascular aneurysm repair with unibody endograft and anatomical fixation / Silingardi, R.; Andreoli, F.; saiTTa, G. M.; Leone, N.; Migliari, M.; Gennai, S.. - In: JOURNAL OF CARDIOVASCULAR SURGERY. - ISSN 0021-9509. - 61:6(2020), pp. 720-728. [10.23736/S0021-9509.19.11076-2]
Silingardi, R.; Andreoli, F.; saiTTa, G. M.; Leone, N.; Migliari, M.; Gennai, S.
File in questo prodotto:
File Dimensione Formato  
J cardiovascular surgery.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 5.93 MB
Formato Adobe PDF
5.93 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1237549
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact