Photovoltaic energy conversion has been on the spotlight of scientific research for several years. Special attention was paid to the grid-connected inverters that do not feature an insulation transformer (transformerless topologies). In this framework, Neutral Point Clamped inverters have gained interest due to the low ground leakage current. Recently, the research has been focused on high-efficiency MOSFET-based topologies. In this paper an Active-NPC topology is equipped with 650V ROHM SiC devices. A new modulation strategy that allows to exploit the characteristics of Sic MOSFETs, is proposed. It permits to obtain very high efficiency due to the parallel operation of the devices during the freewheeling phases of the inverter output current. Simulation and experimental results show the benefits of this choice.

Performance evaluation of a 3-level ANPC photovoltaic grid-connected inverter with 650V SiC devices and optimized PWM / Barater, D.; Concari, C.; Buticchi, G.; Gurpinar, E.; De, D.; Castellazzi, A.. - (2014), pp. 2233-2240. (Intervento presentato al convegno 2014 IEEE Energy Conversion Congress and Exposition (ECCE) tenutosi a Pittsburgh, PA, USA nel 2014) [10.1109/ECCE.2014.6953701].

Performance evaluation of a 3-level ANPC photovoltaic grid-connected inverter with 650V SiC devices and optimized PWM

Barater D.;
2014

Abstract

Photovoltaic energy conversion has been on the spotlight of scientific research for several years. Special attention was paid to the grid-connected inverters that do not feature an insulation transformer (transformerless topologies). In this framework, Neutral Point Clamped inverters have gained interest due to the low ground leakage current. Recently, the research has been focused on high-efficiency MOSFET-based topologies. In this paper an Active-NPC topology is equipped with 650V ROHM SiC devices. A new modulation strategy that allows to exploit the characteristics of Sic MOSFETs, is proposed. It permits to obtain very high efficiency due to the parallel operation of the devices during the freewheeling phases of the inverter output current. Simulation and experimental results show the benefits of this choice.
2014
2014 IEEE Energy Conversion Congress and Exposition (ECCE)
Pittsburgh, PA, USA
2014
2233
2240
Barater, D.; Concari, C.; Buticchi, G.; Gurpinar, E.; De, D.; Castellazzi, A.
Performance evaluation of a 3-level ANPC photovoltaic grid-connected inverter with 650V SiC devices and optimized PWM / Barater, D.; Concari, C.; Buticchi, G.; Gurpinar, E.; De, D.; Castellazzi, A.. - (2014), pp. 2233-2240. (Intervento presentato al convegno 2014 IEEE Energy Conversion Congress and Exposition (ECCE) tenutosi a Pittsburgh, PA, USA nel 2014) [10.1109/ECCE.2014.6953701].
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.