Background: Sleep apnea (SA) is a risk factor for atrial fibrillation (AF). Advanced pacemakers are now able to calculate indexes of SA severity. Hypothesis: We investigated the changes in pacemaker-measured indexes of SA, we assessed their predictive value for AF occurrence and the associated risk of stroke and death at long-term. Methods: We enrolled 439 recipients of a pacemaker endowed with an algorithm for the calculation of a Respiratory Disturbance Index (RDI). The RDI variability was measured over the first 12 months after implantation, as well as its potential association with the occurrence of AF, defined as device-detected cumulative AF burden ≥6 hoursours in a day. Results: The individual RDI mean was 30 ± 18 episodes/h, and the RDI maximum was 59 ± 21 episodes/h. RDI ≥30 episodes/h was detected in 351 (80%) patients during at least one night. The proportion of nights with RDI ≥30 episodes/h was 14% (2%-36%). AF ≥6 hours was detected in 129 (29%) patients during the first 12 months. The risk of AF was higher in patients with RDI maximum ≥63 episodes/h (HR:1.74; 95%CI: 1.22-2.48; P =.001) and with RDI mean ≥ 46 episodes/h (HR:1.63; 95%CI: 1.03-2.57; P =.014). The risk of all-cause death or stroke was higher in patients with AF burden ≥6 hours (HR:1.75; 95%CI: 1.06-2.86; P =.016). Moreover, among patients with no previous history of AF the risk was higher in those with RDI maximum ≥63 episodes/h (HR:1.96; 95%CI: 1.06-3.63; P =.031). Conclusions: Pacemaker-detected SA showed a considerable variability during follow-up. We confirmed the association between RDI and higher risk of AF, and we observed an association between higher RDI maximum and all-cause death or stroke among patients with no previous history of AF.
Continuous monitoring of sleep-disordered breathing with pacemakers: Indexes for risk stratification of atrial fibrillation and risk of stroke / Mazza, A.; Bendini, M. G.; Leggio, M.; De Cristofaro, R.; Valsecchi, S.; Boriani, G.. - In: CLINICAL CARDIOLOGY. - ISSN 0160-9289. - 43:12(2020), pp. 1609-1615. [10.1002/clc.23489]
Continuous monitoring of sleep-disordered breathing with pacemakers: Indexes for risk stratification of atrial fibrillation and risk of stroke
De Cristofaro R.;Boriani G.
2020
Abstract
Background: Sleep apnea (SA) is a risk factor for atrial fibrillation (AF). Advanced pacemakers are now able to calculate indexes of SA severity. Hypothesis: We investigated the changes in pacemaker-measured indexes of SA, we assessed their predictive value for AF occurrence and the associated risk of stroke and death at long-term. Methods: We enrolled 439 recipients of a pacemaker endowed with an algorithm for the calculation of a Respiratory Disturbance Index (RDI). The RDI variability was measured over the first 12 months after implantation, as well as its potential association with the occurrence of AF, defined as device-detected cumulative AF burden ≥6 hoursours in a day. Results: The individual RDI mean was 30 ± 18 episodes/h, and the RDI maximum was 59 ± 21 episodes/h. RDI ≥30 episodes/h was detected in 351 (80%) patients during at least one night. The proportion of nights with RDI ≥30 episodes/h was 14% (2%-36%). AF ≥6 hours was detected in 129 (29%) patients during the first 12 months. The risk of AF was higher in patients with RDI maximum ≥63 episodes/h (HR:1.74; 95%CI: 1.22-2.48; P =.001) and with RDI mean ≥ 46 episodes/h (HR:1.63; 95%CI: 1.03-2.57; P =.014). The risk of all-cause death or stroke was higher in patients with AF burden ≥6 hours (HR:1.75; 95%CI: 1.06-2.86; P =.016). Moreover, among patients with no previous history of AF the risk was higher in those with RDI maximum ≥63 episodes/h (HR:1.96; 95%CI: 1.06-3.63; P =.031). Conclusions: Pacemaker-detected SA showed a considerable variability during follow-up. We confirmed the association between RDI and higher risk of AF, and we observed an association between higher RDI maximum and all-cause death or stroke among patients with no previous history of AF.File | Dimensione | Formato | |
---|---|---|---|
Clinical Cardiology - 2020 - Mazza - Continuous monitoring of sleep‐disordered breathing with pacemakers Indexes for risk.pdf
Open access
Tipologia:
Versione pubblicata dall'editore
Dimensione
1.67 MB
Formato
Adobe PDF
|
1.67 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris