Microelectrode arrays are used for recording and stimulation in neurosciences both in vitro and in vivo. The electrodeposition of conductive polymers, such as poly(3,4-ethylene dioxythiophene) (PEDOT), is widely adopted to improve both the in vivo recording and the charge injection limit of metallic microelectrodes. The workhorse of conductive polymers in the neurosciences is PEDOT:PSS, where PSS represents polystyrene-sulfonate. In this paper, the counterion is the fluorinated polymer Nafion, so the composite PEDOT:Nafion is deposited onto a flexible neural microelectrode array. PEDOT:Nafion coated electrodes exhibit comparable in vivo recording capability to the reference PEDOT:PSS, providing a large signal-to-noise ratio in a murine animal model. Importantly, PEDOT:Nafion exhibits a minimized polarization during electrical stimulation, thereby resulting in an improved charge injection limit equal to 4.4 mC cm−2, almost 80% larger than the 2.5 mC cm−2 that is observed for PEDOT:PSS.

Electrodeposited PEDOT:Nafion Composite for Neural Recording and Stimulation / Carli, S.; Bianchi, M.; Zucchini, E.; Di Lauro, M.; Prato, M.; Murgia, M.; Fadiga, L.; Biscarini, F.. - In: ADVANCED HEALTHCARE MATERIALS. - ISSN 2192-2659. - 8:19(2019), pp. 1-10. [10.1002/adhm.201900765]

Electrodeposited PEDOT:Nafion Composite for Neural Recording and Stimulation

Bianchi M.;Di Lauro M.;Murgia M.;Biscarini F.
2019

Abstract

Microelectrode arrays are used for recording and stimulation in neurosciences both in vitro and in vivo. The electrodeposition of conductive polymers, such as poly(3,4-ethylene dioxythiophene) (PEDOT), is widely adopted to improve both the in vivo recording and the charge injection limit of metallic microelectrodes. The workhorse of conductive polymers in the neurosciences is PEDOT:PSS, where PSS represents polystyrene-sulfonate. In this paper, the counterion is the fluorinated polymer Nafion, so the composite PEDOT:Nafion is deposited onto a flexible neural microelectrode array. PEDOT:Nafion coated electrodes exhibit comparable in vivo recording capability to the reference PEDOT:PSS, providing a large signal-to-noise ratio in a murine animal model. Importantly, PEDOT:Nafion exhibits a minimized polarization during electrical stimulation, thereby resulting in an improved charge injection limit equal to 4.4 mC cm−2, almost 80% larger than the 2.5 mC cm−2 that is observed for PEDOT:PSS.
2019
8
19
1
10
Electrodeposited PEDOT:Nafion Composite for Neural Recording and Stimulation / Carli, S.; Bianchi, M.; Zucchini, E.; Di Lauro, M.; Prato, M.; Murgia, M.; Fadiga, L.; Biscarini, F.. - In: ADVANCED HEALTHCARE MATERIALS. - ISSN 2192-2659. - 8:19(2019), pp. 1-10. [10.1002/adhm.201900765]
Carli, S.; Bianchi, M.; Zucchini, E.; Di Lauro, M.; Prato, M.; Murgia, M.; Fadiga, L.; Biscarini, F.
File in questo prodotto:
File Dimensione Formato  
carli2019.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 1.59 MB
Formato Adobe PDF
1.59 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1223016
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 56
social impact