Robot geometrical calibration aims at reducing the global positioning accuracy of a robotic arm by correcting the theoretical values of the kinematic parameters. A novel method for the geometrical calibration of robotic arms used in industrial applications is proposed. The proposed approach mainly focuses on the final positional accuracy of the robotic tool center point (TCP) when executing an industrial task rather than on the accurate estimation of the kinematic parameters themselves, as done so far by many calibration methods widely discussed in literature. A real industrial use-case is presented, and the steps of the proposed calibration procedure for the robotic arm are described. Experimental methodology and results for the identification of geometrical parameters are also discussed. A practical validation of the final positional accuracy of the robotic arm (after kinematic calibration) was performed, and experimental results validated the proposed procedure, proving its feasibility and effectiveness in the considered industrial scenario.

Geometrical calibration of a 6-axis robotic arm for high accuracy manufacturing task / Lattanzi, L.; Cristalli, C.; Massa, D.; Boria, S.; Lepine, P.; Pellicciari, M.. - In: INTERNATIONAL JOURNAL, ADVANCED MANUFACTURING TECHNOLOGY. - ISSN 0268-3768. - 111:7-8(2020), pp. 1813-1829. [10.1007/s00170-020-06179-9]

Geometrical calibration of a 6-axis robotic arm for high accuracy manufacturing task

Lattanzi L.
;
Boria S.;Pellicciari M.
2020

Abstract

Robot geometrical calibration aims at reducing the global positioning accuracy of a robotic arm by correcting the theoretical values of the kinematic parameters. A novel method for the geometrical calibration of robotic arms used in industrial applications is proposed. The proposed approach mainly focuses on the final positional accuracy of the robotic tool center point (TCP) when executing an industrial task rather than on the accurate estimation of the kinematic parameters themselves, as done so far by many calibration methods widely discussed in literature. A real industrial use-case is presented, and the steps of the proposed calibration procedure for the robotic arm are described. Experimental methodology and results for the identification of geometrical parameters are also discussed. A practical validation of the final positional accuracy of the robotic arm (after kinematic calibration) was performed, and experimental results validated the proposed procedure, proving its feasibility and effectiveness in the considered industrial scenario.
2020
111
7-8
1813
1829
Geometrical calibration of a 6-axis robotic arm for high accuracy manufacturing task / Lattanzi, L.; Cristalli, C.; Massa, D.; Boria, S.; Lepine, P.; Pellicciari, M.. - In: INTERNATIONAL JOURNAL, ADVANCED MANUFACTURING TECHNOLOGY. - ISSN 0268-3768. - 111:7-8(2020), pp. 1813-1829. [10.1007/s00170-020-06179-9]
Lattanzi, L.; Cristalli, C.; Massa, D.; Boria, S.; Lepine, P.; Pellicciari, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1222223
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 20
social impact