OBJECTIVES The aim of this study is to evaluate the ease of use and the advantages of Sorin Pericarbon Freedom (SPF) stentless valve in cases of acute bacterial endocarditis and to check the intermediate-term results after the implant of SPF with respect to resistance to infection, valve deterioration and durability. METHODS Between June 2003 and February 2015, 26 patients with active aortic valve bacterial endocarditis underwent aortic valve replacement with SPF pericardial stentless aortic prosthesis. The mean age was 57 ± 18 years; 73% of the patients were in preoperative NYHA class III and VI. Mean Logistic EuroSCORE was 14.2 ± 12.7. Endocarditis occurred in 18 patients with native valves, and in 9 patients with prosthetic valves (4 mechanical aortic valve prostheses; 5 aortic bioprostheses). Aortic root abscesses were observed in 16 cases (61.5%). Surgery was emergent in 3 cases (11.5%). Redo surgery was performed in 9 cases (35%). Cumulative follow-up was 126.8 patient-years (mean 4.9 ± 3.3 years). RESULTS Operative hospital mortality was 0% for all patients. Residual mean prosthetic gradient at discharge was 9.4 ± 3.6 mmHg. Neither residual aortic incompetence nor residual abscess cavity was observed at discharge. Mean ejection fraction at discharge was 54 ± 8% (Min; Max: 35%; 65%). A total of 4 patients died at follow-up, all for non-cardiac causes. One patient was lost to follow-up. Two patients (8%) underwent non-valve-related reoperation with 0% mortality. Residual mean gradient at follow-up was 7.2 ± 2.1 mmHg. Three patients (17%) presented with mild/moderate aortic incompetence and 89% of patients were in NYHA Class I-II at follow-up. At 9 years, actuarial freedom from valve-related reoperation and from structural valve deterioration was 100%. CONCLUSIONS The SPF aortic prosthesis is a true pericardial stentless prosthesis suitable for the treatment of acute bacterial endocarditis. Intermediate-time results in terms of freedom from reoperation, structural valve deterioration and resistance to infections are satisfactory. Haemodynamic performances are excellent since a complete exclusion of aortic root abscesses is achieved without any reduction of the aortic annular diameter, usually due to marsupialization or patch closure of the infected cavities.

Benefits and medium-term outcome of the Sorin Pericarbon Freedom stentless aortic prosthesis in cases of acute bacterial endocarditis / Stefanelli, G.; Pirro, F.; Meli, M.; Trevisan, D.; Telesca, M.; Campisano, B.; Mussini, C.; Barbieri, A.. - In: INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY. - ISSN 1569-9293. - 23:4(2016), pp. 593-598. [10.1093/icvts/ivw176]

Benefits and medium-term outcome of the Sorin Pericarbon Freedom stentless aortic prosthesis in cases of acute bacterial endocarditis

Meli M.;Trevisan D.;Mussini C.;Barbieri A.
2016

Abstract

OBJECTIVES The aim of this study is to evaluate the ease of use and the advantages of Sorin Pericarbon Freedom (SPF) stentless valve in cases of acute bacterial endocarditis and to check the intermediate-term results after the implant of SPF with respect to resistance to infection, valve deterioration and durability. METHODS Between June 2003 and February 2015, 26 patients with active aortic valve bacterial endocarditis underwent aortic valve replacement with SPF pericardial stentless aortic prosthesis. The mean age was 57 ± 18 years; 73% of the patients were in preoperative NYHA class III and VI. Mean Logistic EuroSCORE was 14.2 ± 12.7. Endocarditis occurred in 18 patients with native valves, and in 9 patients with prosthetic valves (4 mechanical aortic valve prostheses; 5 aortic bioprostheses). Aortic root abscesses were observed in 16 cases (61.5%). Surgery was emergent in 3 cases (11.5%). Redo surgery was performed in 9 cases (35%). Cumulative follow-up was 126.8 patient-years (mean 4.9 ± 3.3 years). RESULTS Operative hospital mortality was 0% for all patients. Residual mean prosthetic gradient at discharge was 9.4 ± 3.6 mmHg. Neither residual aortic incompetence nor residual abscess cavity was observed at discharge. Mean ejection fraction at discharge was 54 ± 8% (Min; Max: 35%; 65%). A total of 4 patients died at follow-up, all for non-cardiac causes. One patient was lost to follow-up. Two patients (8%) underwent non-valve-related reoperation with 0% mortality. Residual mean gradient at follow-up was 7.2 ± 2.1 mmHg. Three patients (17%) presented with mild/moderate aortic incompetence and 89% of patients were in NYHA Class I-II at follow-up. At 9 years, actuarial freedom from valve-related reoperation and from structural valve deterioration was 100%. CONCLUSIONS The SPF aortic prosthesis is a true pericardial stentless prosthesis suitable for the treatment of acute bacterial endocarditis. Intermediate-time results in terms of freedom from reoperation, structural valve deterioration and resistance to infections are satisfactory. Haemodynamic performances are excellent since a complete exclusion of aortic root abscesses is achieved without any reduction of the aortic annular diameter, usually due to marsupialization or patch closure of the infected cavities.
2016
23
4
593
598
Benefits and medium-term outcome of the Sorin Pericarbon Freedom stentless aortic prosthesis in cases of acute bacterial endocarditis / Stefanelli, G.; Pirro, F.; Meli, M.; Trevisan, D.; Telesca, M.; Campisano, B.; Mussini, C.; Barbieri, A.. - In: INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY. - ISSN 1569-9293. - 23:4(2016), pp. 593-598. [10.1093/icvts/ivw176]
Stefanelli, G.; Pirro, F.; Meli, M.; Trevisan, D.; Telesca, M.; Campisano, B.; Mussini, C.; Barbieri, A.
File in questo prodotto:
File Dimensione Formato  
ivw176.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 337.01 kB
Formato Adobe PDF
337.01 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1220765
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact